When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  3. IDC (electrical connector) - Wikipedia

    en.wikipedia.org/wiki/IDC_(electrical_connector)

    An insulation-displacement contact (IDC), also known as insulation-piercing contact (IPC), is an electrical connector designed to be connected to the conductor(s) of an insulated cable by a connection process which forces a selectively sharpened blade or blades through the insulation, bypassing the need to strip the conductors of insulation ...

  4. Tri-rated cable - Wikipedia

    en.wikipedia.org/wiki/Tri-rated_cable

    BS 6231 is a British Standard, last revised in 2006 by the BSI Group. [4] This standard specifies the performance and construction requirements of electrical cables that are single core, non-sheathed, PVC-insulated and rated 600/1000 V. Wire meeting the requirements of type CK of this standard is used as tri-rated wire.

  5. Mineral-insulated copper-clad cable - Wikipedia

    en.wikipedia.org/wiki/Mineral-insulated_copper...

    PVC-sheathed MICC cable. Conductor cross section area is 1.5 mm 2; overall diameter is 7.2 mm. Mineral-insulated cables at a panel board. Mineral-insulated copper-clad cable is a variety of electrical cable made from copper conductors inside a copper sheath, insulated by inorganic magnesium oxide powder.

  6. Coaxial cable - Wikipedia

    en.wikipedia.org/wiki/Coaxial_cable

    Coaxial cable insulation may degrade, requiring replacement of the cable, especially if it has been exposed to the elements on a continuous basis. The shield is normally grounded, and if even a single thread of the braid or filament of foil touches the center conductor, the signal will be shorted causing significant or total signal loss.

  7. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    Also, the size of the aluminum wire needs to be larger compared to copper wire used for the same circuit due to the increased resistance of the aluminum alloys. For example, a 15 A branch circuit supplying standard lighting fixtures can be installed with either #14 AWG copper building wire or #12 AWG aluminum building wire according to the NEC ...

  8. High-voltage cable - Wikipedia

    en.wikipedia.org/wiki/High-voltage_cable

    High voltage is defined as any voltage over 1000 volts. [3] Those of 2 to 33 kV are usually called medium voltage cables, those over 50 kV high voltage cables.. Modern HV cables have a simple design consisting of a few parts: the conductor, the conductor shield, the insulation, the insulation shield, the metallic shield, and the jacket.

  9. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    The most commonly used insulation type in AC electrical distribution systems throughout North America is THHN ("Thermoplastic High Heat-resistant Nylon-coated" [17]). This is a specification for PVC insulation (other thermoplastics are permitted, but rarely used) with a nylon jacket for abrasion resistance. THHN is suitable for dry or damp ...