When.com Web Search

  1. Ads

    related to: radiant heat over existing slab calculator free fire today

Search results

  1. Results From The WOW.Com Content Network
  2. Sol-air temperature - Wikipedia

    en.wikipedia.org/wiki/Sol-air_temperature

    Sol-air temperature (T sol-air) is a variable used to calculate cooling load of a building and determine the total heat gain through exterior surfaces. It is an improvement over: = Where: = rate of heat transfer [W] = heat transfer surface area [m 2]

  3. Radiant heating and cooling - Wikipedia

    en.wikipedia.org/wiki/Radiant_heating_and_cooling

    Radiant heating and cooling is a category of HVAC technologies that exchange heat by both convection and radiation with the environments they are designed to heat or cool. There are many subcategories of radiant heating and cooling, including: "radiant ceiling panels", [ 1 ] "embedded surface systems", [ 1 ] "thermally active building systems ...

  4. Building insulation material - Wikipedia

    en.wikipedia.org/wiki/Building_insulation_material

    At night the absence of heat (i.e. cold) is the exact same phenomenon, with the heat radiating described mathematically as the linear opposite. Radiant barriers prevent radiant heat transfer equally in both directions. However, heat flow to and from surfaces also occurs via convection, which in some geometries is different in different directions.

  5. Rate of heat flow - Wikipedia

    en.wikipedia.org/wiki/Rate_of_heat_flow

    The rate of heat flow is the amount of heat that is transferred per unit of time in some material, usually measured in watts (joules per second). Heat is the flow of thermal energy driven by thermal non-equilibrium, so the term 'heat flow' is a redundancy (i.e. a pleonasm). Heat must not be confused with stored thermal energy, and moving a hot ...

  6. Passive solar building design - Wikipedia

    en.wikipedia.org/wiki/Passive_solar_building_design

    Provided the slab has air channels like the Trombe wall, which run through it in the north-south direction and are vented to the interior air space through the concrete slab floor just inside the north and south walls, vigorous air thermosiphoning through the slab still occurs as in the vertical Trombe wall, distributing the impounded heat ...

  7. Heating film - Wikipedia

    en.wikipedia.org/wiki/Heating_film

    Heating films can be directly installed to provide underfloor heating, wall radiant heating and ceiling radiant heating. The films can also be used in heating panels to produce wall or ceiling panel heaters. Although heating films do not usually run at very high temperatures (typically 30 °C (86 °F) on floors and up to 40 °C (104 °F) on ...