Tree limbs cause a short circuit, triggering an electrical arc during a storm. A short circuit (sometimes abbreviated to short or s/c) is an electrical circuit that allows a current to travel along an unintended path with no or very low electrical impedance. This results in an excessive current flowing through the circuit.
Initial reports suggest that the fire may have been caused by an electrical short circuit within an oxygen concentrator. Eyewitness accounts indicate that a nurse allegedly lit a matchstick while handling an oxygen cylinder, igniting the highly flammable environment of the NICU.
A sudden fail-open fault can cause multiple secondary failures if it is fast and the circuit contains an inductance; this causes large voltage spikes, which may exceed 500 volts. A broken metallisation on a chip may thus cause secondary overvoltage damage. [1] Thermal runaway can cause sudden failures including melting, fire or explosions.
Overhead power lines are easiest to diagnose since the problem is usually obvious, e.g., a tree has fallen across the line, or a utility pole is broken and the conductors are lying on the ground. Locating faults in a cable system can be done either with the circuit de-energized, or in some cases, with the circuit under power.
If an electrical circuit is established by electrodes introduced in the body, bypassing the skin, then the potential for lethality is much higher if a circuit through the heart is established. This is known as a microshock. Currents of only 10 μA can be sufficient to cause fibrillation in this case with a probability of 0.2%. [22]
A voltage sag (U.S. English) or voltage dip [1] (British English) is a short-duration reduction in the voltage of an electric power distribution system. It can be caused by high current demand such as inrush current (starting of electric motors, transformers, heaters, power supplies) or fault current (overload or short circuit) elsewhere on the system.
A burn in a plug caused by an electric arc during a short circuit. Undesired or unintended electric arcing can have detrimental effects on electric power transmission, distribution systems and electronic equipment. Devices which may cause arcing include switches, circuit breakers, relay contacts, fuses and poor cable terminations.
The short circuit ratio (SCR) is an indicator of the strength of a network bus about the rated power of a device and is frequently used as a measure of system strength. A higher SCR value indicates a stronger system, meaning that the impact of disturbances on voltage and other variables will be minimized.