Search results
Results From The WOW.Com Content Network
Symmastia is a condition defined as a confluence of the breast tissue of both breasts across the intermammary cleft that normally divides them. It can be surgically corrected by a plastic surgeon through symmastia revision. [54] Symmastia can either be a congenital anomaly or iatrogenic. [55]
Time gain compensation (TGC) is a setting applied in diagnostic ultrasound imaging to account for tissue attenuation. [1] By increasing the received signal intensity with depth, the artifacts in the uniformity of a B-mode image intensity are reduced.
When the primary beam passes through the body, some of the radiation is absorbed in a process known as attenuation. Anatomy that is denser has a higher rate of attenuation than anatomy that is less dense, so bone will absorb more X-rays than soft tissue. What remains of the primary beam after attenuation is known as the remnant beam. The ...
From the cosmetological point of view, it is an important aesthetic component of the breast which should be taken into consideration during various kinds of breast surgery. [1] [2] Histologically, the inframammary fold is an intrinsic dermal structure consisting of regular arrays of collagen held in place by a specialized superficial fascia ...
In order to localize this signal attenuation to get images of diffusion one has to combine the pulsed magnetic field gradient pulses used for MRI (aimed at localization of the signal, but those gradient pulses are too weak to produce a diffusion related attenuation) with additional "motion-probing" gradient pulses, according to the Stejskal and ...
X-ray attenuation of CBCT acquisition systems currently produces different HU values for similar bony and soft tissue structures in different areas of the scanned volume (e.g. dense bone has a specific image value at the level of the menton, but the same bone has a significantly different image value at the level of the cranial base).
A set of many such projections under different angles organized in 2D is called a sinogram (see Fig. 3). In X-ray CT, the line integral represents the total attenuation of the beam of X-rays as it travels in a straight line through the object. As mentioned above, the resulting image is a 2D (or 3D) model of the attenuation coefficient.
Spectral imaging is an umbrella term for energy-resolved X-ray imaging in medicine. [1] The technique makes use of the energy dependence of X-ray attenuation to either increase the contrast-to-noise ratio, or to provide quantitative image data and reduce image artefacts by so-called material decomposition.