HC-12a, also called ES-12a, OZ-12a, DURACOOL 12a [1] and Hydrocarbon Blend B, is marketed as a "drop-in" replacement refrigerant for R-12 and other refrigerants. HC-12a is a mixture of hydrocarbons, specifically propane (R-290) and isobutane (R-600a), and is therefore considered nearly non-ozone-depleting.
A thermal expansion valve or thermostatic expansion valve (often abbreviated as TEV, TXV, or TX valve) is a component in vapor-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the evaporator ...
R-407C is a mixture of hydrofluorocarbons used as a refrigerant. It is a zeotropic blend of difluoromethane (R-32), pentafluoroethane (R-125), and 1,1,1,2-tetrafluoroethane (R-134a). Difluoromethane serves to provide the heat capacity, pentafluoroethane decreases flammability, tetrafluoroethane reduces pressure. [1] R-407C cylinders are colored ...
Some systems deal with flash-gas by separating it from the refrigerant that goes to the evaporator, as that portion of the refrigerant already evaporated and will only increase superheating. [6] One key feature when preventing flash-gas is the diameter of the piping. If the pipes are too thin and long, loss of pressure and friction tend to occur.
Air-conditioning and refrigeration equipment capacity in the U.S. is often specified in "tons" (of refrigeration). Many manufacturers also specify capacity in Btu/h, especially when specifying the performance of smaller equipment.
Cooling capacity is the measure of a cooling system's ability to remove heat. [1] It is equivalent to the heat supplied to the evaporator/boiler part of the refrigeration cycle and may be called the "rate of refrigeration" or "refrigeration capacity".
In such an air conditioning system, the accumulator also prevents the liquid refrigerant from reaching the compressor during low cooling demand periods. The air, often after being filtered by a cabin air filter , is blown by an adjustable speed electric powered centrifugal fan across the evaporator, causing the liquid part of the cold ...
According to ASHRAE standard 34, the R-number of a chemical refrigerant is assigned systematically according to its molecular structure and has between two and four digits. If there are carbon -carbon multiple bonds , there are four digits in all: the number of these bonds is the first digit and the number of carbon atoms minus one (C-1) is next.