When.com Web Search

  1. Ad

    related to: power factor capacitor calculator for generator battery system reviews

Search results

  1. Results From The WOW.Com Content Network
  2. Load bank - Wikipedia

    en.wikipedia.org/wiki/Load_bank

    A capacitive load bank or capacitor bank is similar to an inductive load bank in rating and purpose, except leading power factor loads are created, so reactive power is supplied from these loads to the system instead of vice versa. Hence for a mostly inductive load this can bring the power factor closer to unity improving the quality of supply.

  3. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    The power factor in a single-phase circuit (or balanced three-phase circuit) can be measured with the wattmeter-ammeter-voltmeter method, where the power in watts is divided by the product of measured voltage and current. The power factor of a balanced polyphase circuit is the same as that of any phase. The power factor of an unbalanced ...

  4. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    Power factor correcting capacitors can be added externally to neutralize a constant amount of the variable reactive excitation current. After starting, an induction generator can use a capacitor bank to produce reactive excitation current, but the isolated power system's voltage and frequency are not self-regulating and destabilize readily.

  5. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    The fixed speed wind turbines without a power converter (also known as "Type 1" and "Type 2" [5]) cannot be used for voltage control. They simply absorb the reactive power (like any typical induction machine), so a switched capacitor bank is usually used to correct the power factor to unity. [7] Capability curve of a photovoltaic generator

  6. Synchronous condenser - Wikipedia

    en.wikipedia.org/wiki/Synchronous_condenser

    The reactive power produced by a capacitor bank is in direct proportion to the square of its terminal voltage, and if the system voltage decreases, the capacitors produce less reactive power, when it is most needed, [2] while if the system voltage increases the capacitors produce more reactive power, which exacerbates the problem. In contrast ...

  7. Inrush current - Wikipedia

    en.wikipedia.org/wiki/Inrush_current

    Instantaneous current declines to steady-state current as the capacitor reaches full charge. In the case of open circuit, the capacitor will be charged to the peak AC voltage (one cannot actually charge a capacitor with AC line power, so this refers to a varying but unidirectional voltage; e.g., the voltage output from a rectifier).

  8. Static VAR compensator - Wikipedia

    en.wikipedia.org/wiki/Static_VAR_compensator

    In Electrical Engineering, a static VAR compensator (SVC) is a set of electrical devices for providing fast-acting reactive power on high-voltage electricity transmission networks. [1] [2] SVCs are part of the flexible AC transmission system [3] [4] device family, regulating voltage, power factor, harmonics and stabilizing the system. A static ...

  9. AC power - Wikipedia

    en.wikipedia.org/wiki/AC_power

    Transmission connected generators are generally required to support reactive power flow. For example, on the United Kingdom transmission system, generators are required by the Grid Code Requirements to supply their rated power between the limits of 0.85 power factor lagging and 0.90 power factor leading at the designated terminals.