For example, a mass flow rate of 1,000 kg/h of air at 1 atmosphere of absolute pressure is 455 SCFM when defined at 32 °F (0 °C) but 481 SCFM when defined at 60 °F (16 °C). Due to the variability of the definition and the consequences of ambiguity, it is best engineering practice to state what standard conditions are used when communicating ...
SG is the specific gravity of the fluid (for water = 1), ΔP is the pressure drop across the valve (expressed in psi). In more practical terms, the flow coefficient C v is the volume (in US gallons) of water at 60 °F (16 °C) that will flow per minute through a valve with a pressure drop of 1 psi (6.9 kPa) across the valve.
Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.
A set of three water pressure measurements are recorded from two hydrants. One hydrant is known as the residual hydrant or test hydrant and is located on or near the water main where a new water connection is desired. From this test hydrant, a static pressure and a residual pressure will be measured.
If a gaseous emission sample is analyzed and found to contain water vapor and a pollutant concentration of say 40 ppmv, then 40 ppmv should be designated as the "wet basis" pollutant concentration. The following equation can be used to correct the measured "wet basis" concentration to a "dry basis" concentration: [3]
For petroleum gases, the standard cubic foot (scf) is defined as one cubic foot of gas at 60 °F (288.7 K; 15.56 °C) and at normal sea level air pressure. The pressure definition differs between sources, but are all close to normal sea level air pressure. A pressure of 14.696 pounds per square inch (1.00000 atm; 101.325 kPa). [2]
A Fixture Unit is not a flow rate unit but a design factor. A fixture unit is equal to 1 cubic foot (0.028 m 3) of water drained in a 1 + 1 ⁄ 4 inches (32 mm) diameter pipe over one minute. [2] One cubic foot of water is roughly 7.48 US gallons (28.3 L; 6.23 imp gal). A Fixture Unit is used in plumbing design for both water supply and waste ...
An air flow meter is a device similar to an anemometer that measures air flow, i.e. how much air is flowing through a tube. It does not measure the volume of the air passing through the tube, it measures the mass of air flowing through the device per unit time, though Thus air flow meters are simply an application of mass flow meters for the ...