When.com Web Search

  1. Ads

    related to: recommended air velocity in pipes for home hvac ventilation definition

Search results

  1. Results From The WOW.Com Content Network
  2. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each hour.

  3. Glossary of HVAC terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_HVAC_terms

    HVAC (heating, ventilation, and air conditioning) is a major sub discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other factors such as installation cost, ease of maintenance, and energy efficiency. The discipline of HVAC includes a large number of specialized terms and acronyms, many ...

  4. Air Movement and Control Association - Wikipedia

    en.wikipedia.org/wiki/Air_Movement_and_Control...

    The Air Movement and Control Association International, Inc. (AMCA) is an international trade body that sets standards for Heating, Ventilation and Air Conditioning equipment. It rates fan balance and vibration, aerodynamic performance, air density, speed and efficiency.

  5. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.

  6. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Ducts for air pollution control in a 17000 standard cubic feet per minute regenerative thermal oxidizer (RTO). A round galvanized steel duct connecting to a typical diffuser Fire-resistance rated mechanical shaft with HVAC sheet metal ducting and copper piping, as well as "HOW" (Head-Of-Wall) joint between top of concrete block wall and underside of concrete slab, firestopped with ceramic ...

  7. Register (air and heating) - Wikipedia

    en.wikipedia.org/wiki/Register_(air_and_heating)

    The velocity of air through a register is usually kept low enough so that it is masked by background noise. (Higher ambient levels of background noise, such as those in restaurants, allow higher air velocities.) On the other hand, air velocity must be high enough to achieve the desired temperature. [6] Registers are a critical part of the HVAC ...