Search results

  1. Results From The WOW.Com Content Network
  2. Passive nuclear safety - Wikipedia

    en.wikipedia.org/wiki/Passive_nuclear_safety

    Passive nuclear safety is a design approach for safety features, implemented in a nuclear reactor, that does not require any active intervention on the part of the operator or electrical/electronic feedback in order to bring the reactor to a safe shutdown state, in the event of a particular type of emergency (usually overheating resulting from a loss of coolant or loss of coolant flow).

  3. Fail-safe - Wikipedia

    en.wikipedia.org/wiki/Fail-safe

    Unlike inherent safety to a particular hazard, a system being "fail-safe" does not mean that failure is naturally inconsequential, but rather that the system's design prevents or mitigates unsafe consequences of the system's failure. If and when a "fail-safe" system fails, it remains at least as safe as it was before the failure.

  4. Shutdown valve - Wikipedia

    en.wikipedia.org/wiki/Shutdown_valve

    A blowdown valve (BDV) is a type of shutdown valve designed to depressurize a pressure vessel by directing vapour to a flare, vent or blowdown stack in an emergency. BDVs fail-safe to the open position upon failure of the control system. [1] The type of valve, type of actuation and performance measurement are similar to an ESD valve.

  5. Safety valve - Wikipedia

    en.wikipedia.org/wiki/Safety_valve

    An oxygen safety relief valve DN250-safety valves. A safety valve is a valve that acts as a fail-safe.An example of safety valve is a pressure relief valve (PRV), which automatically releases a substance from a boiler, pressure vessel, or other system, when the pressure or temperature exceeds preset limits.

  6. High-integrity pressure protection system - Wikipedia

    en.wikipedia.org/wiki/High-integrity_pressure...

    The HIPPS will shut off the source of the high pressure before the design pressure of the system is exceeded, thus preventing loss of containment through rupture of a line or vessel. Therefore, a HIPPS is considered as a barrier between a high-pressure and a low-pressure section of an installation.

  7. Partial stroke testing - Wikipedia

    en.wikipedia.org/wiki/Partial_stroke_testing

    λ D = The dangerous failure rate of the safety function. TI FC = The full closure interval, i.e. how often the valve must be full closed for testing. TI PST = The partial stroke test interval. The proof test coverage is a measure of how effective the partial stroke test is and the higher the PTC the greater the effect of the test.

  8. Desmodromic valve - Wikipedia

    en.wikipedia.org/wiki/Desmodromic_valve

    A desmodromic valve is a reciprocating engine poppet valve that is positively closed by a cam and leverage system, rather than by a more conventional spring. The valves in a typical four-stroke engine allow the air/fuel mixture into the cylinder at the beginning of the cycle and exhaust spent gases at the end of the cycle. In a conventional ...

  9. Safety-critical system - Wikipedia

    en.wikipedia.org/wiki/Safety-critical_system

    In a similar vein, an industrial or domestic burner controller can fail, but must fail in a safe mode (i.e. turn combustion off when they detect faults). Famously, nuclear weapon systems that launch-on-command are fail-safe, because if the communications systems fail, launch cannot be commanded. Railway signaling is designed to be fail-safe.