A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
A ground fault circuit interrupter (GFCI) is required for all receptacles in wet locations defined in the Code. The NEC also has rules about how many circuits and receptacles should be placed in a given residential dwelling, and how far apart they can be in a given type of room, based upon the typical cord length of small appliances.
Receptacles protected in this manner or with a GFCI circuit breaker should be labeled "GFCI protected". (Outside North America these are referred to as a "Residual-current device" or RCD.) Arc-Fault Circuit Interrupter (AFCI) protection is required to protect nearly all finished areas of a home with the exception of bathrooms. This device ...
When it comes to electrical systems, ungrounded receptacles, exposed light bulbs, double-tapped circuit breakers, and malfunctioning GFCI outlets are all issues a home inspector must note on their ...
In the US and Canada, GFCI protection is required for receptacles in many potentially wet locations, including outside outlets, bathrooms, and some places in kitchens, basements, and crawl spaces. This is an expedient way to provide that protection at the receptacle itself.
A safer and more reliable alternative identified in the US and Canadian electrical codes is to replace the outlet with a Ground Fault Circuit Interrupter (GFCI) breaker outlet. [3] Cheater plugs are also used to break ground loops in audio systems. [5] This practice has been condemned as disregarding electrical safety.
2. A listed branch/feeder-type AFCI that is installed at the origin of the branch circuit working in combination with the listed outlet branch-circuit-type AFCI (OBC AFCI) installed at the first outlet box which must also be marked that it is the first outlet box of the branch circuit. 3.
The earth connection is achieved with a three-conductor mains cable, typically ending with three-prong AC connector which plugs into a corresponding AC outlet. Plugs are designed such that the connection to the protective earth conductor should be the first connection when plugged in. It should also be the last to be broken when the plug is ...