When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Potentiometric titration - Wikipedia

    en.wikipedia.org/wiki/Potentiometric_titration

    Measurements, first and second derivative in a potentiometric titration. In analytical chemistry, potentiometric titration is a technique similar to direct titration of a redox reaction. It is a useful means of characterizing an acid. No indicator is used; instead the electric potential is measured across the analyte, typically an electrolyte ...

  3. Karl Fischer titration - Wikipedia

    en.wikipedia.org/wiki/Karl_Fischer_titration

    The volumetric titration is based on the same principles as the coulometric titration, except that the anode solution above now is used as the titrant solution. The titrant consists of an alcohol (ROH), base (B), SO 2 and a known concentration of I 2. Pyridine has been used as the base in this case. One mole of I 2 is consumed for each mole of ...

  4. Kjeldahl method - Wikipedia

    en.wikipedia.org/wiki/Kjeldahl_method

    If boric acid (or some other weak acid) was used, direct acid–base titration is done with a strong acid of known concentration. HCl or H 2 SO 4 can be used. Indirect back titration is used instead if strong acids were used to make the standard acid solution: strong base of known concentration (like NaOH) is used to neutralize the solution. In ...

  5. Iodometry - Wikipedia

    en.wikipedia.org/wiki/Iodometry

    Iodometry, known as iodometric titration, is a method of volumetric chemical analysis, a redox titration where the appearance or disappearance of elementary iodine indicates the end point. Note that iodometry involves indirect titration of iodine liberated by reaction with the analyte, whereas iodimetry involves direct titration using iodine as ...

  6. Titer - Wikipedia

    en.wikipedia.org/wiki/Titer

    The term also has two other, conflicting meanings. In titration, the titer is the ratio of actual to nominal concentration of a titrant, e.g. a titer of 0.5 would require 1/0.5 = 2 times more titrant than nominal. This is to compensate for possible degradation of the titrant solution.

  7. Standard solution - Wikipedia

    en.wikipedia.org/wiki/Standard_solution

    Standard solutions are generally prepared by dissolving a solute of known mass into a solvent to a precise volume, or by diluting a solution of known concentration with more solvent. [1] A standard solution ideally has a high degree of purity and is stable enough that the concentration can be accurately measured after a long shelf time. [2]

  8. Argentometry - Wikipedia

    en.wikipedia.org/wiki/Argentometry

    An example of back titration, the Volhard method, named after Jacob Volhard, involves the addition of excess silver nitrate to the analyte; the silver chloride is filtered, and the remaining silver nitrate is titrated against ammonium thiocyanate, [1] with ferric ammonium sulfate as an indicator which forms blood-red [Fe(OH 2) 5 (SCN)] 2+ at the end point:

  9. Complexometric indicator - Wikipedia

    en.wikipedia.org/wiki/Complexometric_indicator

    A complexometric indicator is an ionochromic dye that undergoes a definite color change in presence of specific metal ions. [1] It forms a weak complex with the ions present in the solution, which has a significantly different color from the form existing outside the complex.