Results From The WOW.Com Content Network
Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor ...
This is a fully enclosed plenum A commercial building with a plenum airspace. A non fully insulated HVAC plenum created by accident can go unnoticed and become a fire hazard, due to cabling installed under the assumption that this will always be a fully enclosed plenum. the fire risk come from that the non fire resistance material of the ...
The return plenum carries the air from several large return grills (vents) to a central air handler for re-heating. The supply plenum directs air from the central unit to the rooms which the system is designed to heat. Regardless of type, all air handlers consist of an air filter, blower, heat exchanger/element/coil, and various controls.
Air streams are mixed to save energy and improve energy efficiency by partially recirculating conditioned air.. The most common application for an air-mixing plenum is the mixing of return air (or extract air) with fresh air to provide a supply air mixture for onward distribution to the building or area which the ventilation system is serving. [1]
HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. " Refrigeration " is sometimes added to the field's abbreviation as HVAC&R or HVACR , or "ventilation" is dropped, as in HACR (as in the designation of HACR-rated circuit breakers ).
The ASHRAE Handbook has had a variety of titles. [5] It began in 1922 as the ASH&VE Guide.In 1973 it became the ASHRAE Handbook, and in 1985 separate publication of inch-pound and international system units versions of the volumes began.
Plenums are the central distribution and collection units for an HVAC system. The return plenum carries the air from several large return grilles (vents) or bell mouths to a central air handler. The supply plenum directs air from the central unit to the rooms which the system is designed to heat or cool.
Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.