  1. Results From The WOW.Com Content Network
  2. Partial discharge - Wikipedia

    en.wikipedia.org/wiki/Partial_discharge

    Data collected during partial discharge testing is compared to measurement values of the same cable gathered during the acceptance-test or to factory quality control standards. This allows simple and quick classification of the dielectric condition (new, strongly aged, faulty) of the device under test and appropriate maintenance and repair ...

  3. Dissolved gas analysis - Wikipedia

    en.wikipedia.org/wiki/Dissolved_gas_analysis

    A Multi Stage Gas Extractor is a device for sampling transformer oil. During 2004, Central Power Research Institute, Bangalore, India introduced a novel method in which a same sample of transformer oil could be exposed to vacuum many times, at ambient temperature, until there is no increase in the volume of extracted gases. This method was ...

  4. Qualitrol - Wikipedia

    en.wikipedia.org/wiki/Qualitrol

    Qualitrol is a condition monitoring technology company headquartered in Fairport, New York.Qualitrol manufacturers and distributes partial discharge monitoring, asset protection equipment and information products for the electrical generation, transmission and distribution industries.

  5. Corona discharge - Wikipedia

    en.wikipedia.org/wiki/Corona_discharge

    A corona discharge is an electrical discharge caused by the ionization of a fluid such as air surrounding a conductor carrying a high voltage. It represents a local region where the air (or other fluid) has undergone electrical breakdown and become conductive, allowing charge to continuously leak off the conductor into the air.

  6. Electrical treeing - Wikipedia

    en.wikipedia.org/wiki/Electrical_treeing

    An analysis of the PD signals collected during the measurement with the proper equipment can allow for the vast majority of location of insulation defects. Usually they are displayed in a partial discharge mapping format. Additional useful information about the device under test can be derived from a phase related depiction of the partial ...

  7. VLF cable testing - Wikipedia

    en.wikipedia.org/wiki/VLF_cable_testing

    Apply VLF in order to detect and measure partial discharge. In this case, the IEEE 400.3 outlines a procedure for assessment and IEC 60270 provides the background for partial discharge testing of high voltage apparatus. The test is typically performed over a range of test voltages to identify the different defects and their inception and ...

  8. Megger Group Limited - Wikipedia

    en.wikipedia.org/wiki/Megger_Group_Limited

    Protective relay test set 1953 Partial discharge (Corona) detection system 1968 Portable digital multimeter 1979 Digital line earth loop impedance tester 1985 Microprocessor-based high current test set 1989 Battery impedance test equipment (BITE) 1990 Automatic 10kV insulation power factor test set 1990 Microprocessor-based protective relay ...

  9. Dielectric barrier discharge - Wikipedia

    en.wikipedia.org/wiki/Dielectric_barrier_discharge

    Dielectric-barrier discharge (DBD) is the electrical discharge between two electrodes separated by an insulating dielectric barrier. [1] Originally called silent (inaudible) discharge and also known as ozone production discharge [2] or partial discharge, [3] it was first reported by Ernst Werner von Siemens in 1857. [4]