Search results
Results From The WOW.Com Content Network
trans-1,3,3,3-Tetrafluoropropene (HFO-1234ze(E), R-1234ze(E)) is a hydrofluoroolefin. It was developed as a "fourth generation" refrigerant to replace fluids such as R-134a, as a blowing agent for foam and aerosol applications, and in air horns and gas dusters. [3] The use of R-134a is being phased out because of its high global warming ...
According to ASHRAE standard 34, the R-number of a chemical refrigerant is assigned systematically according to its molecular structure and has between two and four digits. If there are carbon-carbon multiple bonds, there are four digits in all: the number of these bonds is the first digit and the number of carbon atoms minus one (C-1) is next ...
As a refrigerant, it is designated R-1234yf [1] and marketed under the names Opteon YF by Chemours and as Solstice YF by Honeywell. [3] R-1234yf is also a component of zeotropic refrigerant blend R-454B. HFO-1234yf has a GWP less than carbon dioxide, [4] [2] itself 1,430 times less potent than R-134a. [5]
However, like methane, R-410A has a global warming potential (GWP) that is appreciably worse than CO 2 (GWP = 1) for the time it persists. R-410A is a mixture of 50% HFC-32 and 50% HFC-125. HFC-32 has a 4.9 year lifetime and a 100-year GWP of 675 and HFC-125 has a 29-year lifetime and a 100-year GWP of 3500.
Refrigerants are typically evaluated on both their global warming potential (GWP) and ozone depletion potential (ODP).The GWP scale is standardized to carbon dioxide, where the refrigerant's value is the multiple of the heat that would be absorbed by the same mass of carbon dioxide over a period of time. [11]
R-407C is a mixture of hydrofluorocarbons used as a refrigerant. It is a zeotropic blend of difluoromethane (R-32), pentafluoroethane (R-125), and 1,1,1,2-tetrafluoroethane (R-134a). Difluoromethane serves to provide the heat capacity, pentafluoroethane decreases flammability, tetrafluoroethane reduces pressure. [1] R-407C cylinders are colored ...
2,2-Dichloro-1,1,1-trifluoroethane or HCFC-123 is considered as an alternative to CFC-11 in low pressure refrigeration and HVAC systems, and should not be used in foam blowing processes or solvent applications.
This fluid is called the working fluid. [1] Refrigeration and heat pump technologies often refer to working fluids as refrigerants. Most thermodynamic cycles make use of the latent heat (advantages of phase change) of the working fluid. In case of other cycles the working fluid remains in gaseous phase while undergoing all the processes of the ...