    en.wikipedia.org/wiki/Ampacity

    For example, the United States National Electrical Code, Table 310.15(B)(16), specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30 °C, the conductor surface temperature allowed to be 75 °C. A single insulated conductor ...

  3. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    A full-load wire does heat up slightly due to the metallic resistance of the wire, but this wire heating is factored into the cable's temperature rating. (NEC 310.10) [12] The NEC specifies acceptable numbers of conductors in crowded areas such as inside conduit, referred to as the fill rating.

  4. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking with ridged, grooves or white stripes on the surface of lamp cord.

  5. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  6. Neher–McGrath method - Wikipedia

    en.wikipedia.org/wiki/Neher–McGrath_method

    For wire sizes smaller than AWG No. 2 (33.6 mm 2, 0.0521 sq in), this term is also generally regarded as insignificant. , is the effective thermal resistance between the conductor and the ambient conditions, which can require significant empirical or theoretical effort to estimate. With respect to the AC-sensitive terms, tabular presentation of ...

  7. Electrical conduit - Wikipedia

    en.wikipedia.org/wiki/Electrical_conduit

    FMT is a raceway, but not a conduit and is described in a separate NEC Article 360. It only comes in 1/2" & 3/4" trade sizes, whereas FMC is sized 1/2" ~ 4" trade sizes. NEC 360.2 describes it as: "A raceway that is circular in cross section, flexible, metallic and liquidtight without a nonmetallic jacket."

  8. Circular mil - Wikipedia

    en.wikipedia.org/wiki/Circular_mil

    In Canada and the United States, the Canadian Electrical Code (CEC) and the National Electrical Code (NEC), respectively, use the circular mil to define wire sizes larger than 0000 AWG. In many NEC publications and uses, large wires may be expressed in thousands of circular mils, which is abbreviated in two different ways: kcmil [1] or MCM. [2]

  9. Electrical code - Wikipedia

    en.wikipedia.org/wiki/Electrical_code

    An electrical code is a term for a set of regulations for the design and installation of electrical wiring in a building. The intention of such regulations is to provide standards to ensure electrical wiring systems are safe for people and property, protecting them from electrical shock and fire hazards.