When.com Web Search

  1. Ads

    related to: fresh air intake hvac system cost per square foot

Search results

  1. Results From The WOW.Com Content Network
  2. Dedicated outdoor air system - Wikipedia

    en.wikipedia.org/wiki/Dedicated_outdoor_air_system

    DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...

  3. Manitoba Hydro Place - Wikipedia

    en.wikipedia.org/wiki/Manitoba_Hydro_Place

    The building's bioclimatic, energy-efficient design features a 377 ft (115 m) tall solar chimney, a geo-thermal HVAC system using 280 five-inch tubes bored 380 feet into an underground aquifer, [12] 100% fresh air (24 hours a day, year-round, regardless of outside temperature) [10] and a one-meter-wide double exterior wall with computer ...

  4. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    The total outdoor air intake of the ventilation system (in multiple-zone variable air volume (VAV) systems) might therefore be similar to the airflow required by the 1989 standard. From 1999 to 2010, there was considerable development of the application protocol for ventilation rates.

  5. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Rooftop HVAC unit with view of fresh-air intake vent Ventilation duct with outlet diffuser vent. These are installed throughout a building to move air in or out of rooms. In the middle is a damper to open and close the vent to allow more or less air to enter the space. The control circuit in a household HVAC installation.

  6. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each hour.

  7. Heat recovery ventilation - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_ventilation

    Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...

  1. Ads

    related to: fresh air intake hvac system cost per square foot