  2. Cost of electricity by source - Wikipedia

    en.wikipedia.org/wiki/Cost_of_electricity_by_source

    The levelized cost of electricity (LCOE) is a metric that attempts to compare the costs of different methods of electricity generation consistently. Though LCOE is often presented as the minimum constant price at which electricity must be sold to break even over the lifetime of the project, such a cost analysis requires assumptions about the value of various non-financial costs (environmental ...

  3. Load factor (electrical) - Wikipedia

    en.wikipedia.org/wiki/Load_factor_(electrical)

    load factor = ( [ 57 200 kWh / {30 d × 24 h/d} ] / 436 kW) × 100% = 18.22%; It can be derived from the load profile of the specific device or system of devices. Its value is always less than one because maximum demand is never lower than average demand, since facilities likely never operate at full capacity for the duration of an entire 24 ...

  4. Electricity pricing - Wikipedia

    en.wikipedia.org/wiki/Electricity_pricing

    The simple rate charges a specific dollar per kilowatt hour ($/kWh) consumed. The tiered rate is one of the more common residential rate programs. The tiered rate charges a higher rate as customer usage increases. TOU and demand rates are structured to help maintain and control a utility's peak demand. [6]

  5. Kilowatt-hour - Wikipedia

    en.wikipedia.org/wiki/Kilowatt-hour

    The notation kW/h for the kilowatt-hour is incorrect, as it denotes kilowatt per hour. The hour is a unit of time listed among the non-SI units accepted by the International Bureau of Weights and Measures for use with the SI. [6] An electric heater consuming 1,000 watts (1 kilowatt) operating for one hour uses one kilowatt-hour of energy.

  6. Levelized cost of electricity - Wikipedia

    en.wikipedia.org/wiki/Levelized_cost_of_electricity

    For LCOE to be usable for rank-ordering energy-generation alternatives, caution must be taken to calculate it in "real" terms, i.e. including adjustment for expected inflation. [ 10 ] [ 11 ] An energy efficiency gap phenomenon exists due to observed lack of consideration of and implementation of demand-side energy conservation . [ 12 ]

  7. Electricity billing in the UK - Wikipedia

    en.wikipedia.org/wiki/Electricity_billing_in_the_UK

    MSP kWh is the amount of electricity consumed at the 'meter supply point', which is the customer's meter. GSP kWh is obtained by multiplying the MSP kWh by the Line Loss Factor (LLF, a figure > 1) to include the amount of electricity lost when it is conducted through the distribution network, from the 'grid supply point' to the customer's meter.