Search results
Results From The WOW.Com Content Network
In the less-dangerous instance of a bootleg ground, a short wire jumper is connected between the bonding screw terminal (usually colored green) on a NEMA 5-15R or 5-20R outlet to the neutral (a.k.a. grounded conductor, colored white according to code) or directly to the white neutral wire via a pigtail. This practice is a NEC code violation ...
The ground connection must have a low electrical resistance, because it carries the full antenna current and any resistance in the ground connection will dissipate power from the transmitter. Low-resistance grounds for radio transmitters are normally constructed of a network of cables buried in the earth.
An OPGW cable contains a tubular structure with one or more optical fibers in it, surrounded by layers of steel and aluminum wire. The OPGW cable is run between the tops of high-voltage electricity pylons. The conductive part of the cable serves to bond adjacent towers to earth ground, and shields the high-voltage conductors from lightning ...
The ground rods create a ground plane under the antenna which increases the gain. The ground rods may extend horizontally from the base, but in antennas fed by coaxial cable as shown here they are usually sloped downward to increase the radiation resistance of the antenna from the 36 ohms of a quarter wave monopole closer to 50 ohms, so the ...
For example, NM 14-2 cable contains three conductors (two plus one ground) at 14 gauge, a size typically used for circuits protected at 15 amperes. Circuits with larger currents (such as for electric furnaces, water heaters, air conditioners, or sub-mains to additional circuit panels) will have larger conductors.
A terrestrial cable is a communications cable which crosses land, rather than water. Terrestrial cable may be subterranean (buried) or aerial (suspended from poles ), and may be fiber or copper . [ 1 ] [ 2 ] The term "terrestrial cable" is principally used to distinguish it from submarine cable , [ 3 ] although some overlap exists between the two.
In North American practice, for residential and light commercial buildings fed with a single-phase split 120/240 service, an overhead cable from a transformer on a power pole is run to the service entrance point. The cable is a three conductor twisted "triplex" cable with a bare neutral and two insulated conductors, with no overall cable jacket ...
Strictly speaking, the terms grounding or earthing are meant to refer to an electrical connection to ground/earth. Bonding is the practice of intentionally electrically connecting metallic items not designed to carry electricity. This brings all the bonded items to the same electrical potential as a protection from electrical shock.