The LH- and DLH-Series have been designed for the purpose of extending the use of joists to spans and loads in excess of those covered by Open Web Steel Joists, K-Series. LH-Series Joists have been standardized in depths from 18 inches (460 mm) through 48 inches (1,200 mm), for spans through 96 feet (29,000 mm).
Waffle slabs are preferred for spans greater than 40 feet (12 m), because, for a given mass of concrete, they are much stronger than flat slabs, flat slabs with drop panels, two-way slabs, one-way slabs, and one-way joist slabs. [2] Section of a waffle slab including beam, ribs, and column head
Wall framing in house construction includes the vertical and horizontal members of exterior walls and interior partitions, both of bearing walls and non-bearing walls. . These stick members, referred to as studs, wall plates and lintels (sometimes called headers), serve as a nailing base for all covering material and support the upper floor platforms, which provide the lateral strength along a
Steel studs are gaining popularity as a non-combustible alternative, especially for non load-bearing walls, and are required in some firewalls. In New Zealand, the required lumber size and spacing of wall studs are determined using NZS 3604 Timber-framed buildings table 8.2 for loadbearing walls and table 8.4 for non-loadbearing walls. [4]
A hanger support only exerts a force and prevents a member from acting or translating away in the direction of the hanger. However, this support cannot prevent translational movement in all directions and any rotational movement. [1] [5] This is one of the simplest structural forms in which the elements are in pure tension. Structures of this ...
In engineering, span is the distance between two adjacent structural supports (e.g., two piers) of a structural member (e.g., a beam). Span is measured in the horizontal direction either between the faces of the supports (clear span) or between the centers of the bearing surfaces (effective span): [1] A span can be closed by a solid beam or by ...
Between the joists, the area called a joist-bay, and above the ceiling in some old houses is material called pugging, which was used to deaden sound, insulate, and resist the spread of fire. A joist hanger. In platform framing, the joists may be connected to the rim joist with toenailing or by using a joist hanger. [5]
In structural engineering, a diaphragm is a structural element that transmits lateral loads to the vertical resisting elements of a structure (such as shear walls or frames). Diaphragms are typically horizontal but can be sloped in a gable roof on a wood structure or concrete ramp in a parking garage.