  2. Deadweight tester - Wikipedia

    en.wikipedia.org/wiki/Deadweight_tester

    A dead weight tester (DWT) is a calibration standard method that uses a piston cylinder on which a load is placed to make an equilibrium with an applied pressure underneath the piston. Deadweight testers are secondary standards which means that the pressure measured by a deadweight tester is defined through other quantities: length, mass and ...

  3. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    As an example, a manual process may be used for calibration of a pressure gauge. The procedure requires multiple steps, [12] to connect the gauge under test to a reference master gauge and an adjustable pressure source, to apply fluid pressure to both reference and test gauges at definite points over the span of the gauge, and to compare the ...

  4. Pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Pressure_measurement

    Pressure sensors can alternatively be called pressure transducers, pressure transmitters, pressure senders, pressure indicators, piezometers and manometers, among other names. Pressure is an expression of the force required to stop a fluid from expanding, and is usually stated in terms of force per unit area.

  5. Piping and instrumentation diagram - Wikipedia

    en.wikipedia.org/wiki/Piping_and_instrumentation...

    Piping and instrumentation diagram of pump with storage tank. Symbols according to EN ISO 10628 and EN 62424. A more complex example of a P&ID. A piping and instrumentation diagram (P&ID) is defined as follows: A diagram which shows the interconnection of process equipment and the instrumentation used to control the process.

  6. Load cell - Wikipedia

    en.wikipedia.org/wiki/Load_cell

    Annual re-calibration is considered best practice by many load cell users for ensuring the most accurate measurements. Standard calibration tests will use linearity and repeatability as a calibration guideline as these are both used to determine accuracy. Calibration is conducted incrementally starting working in ascending or descending order.

  7. Small arms ammunition pressure testing - Wikipedia

    en.wikipedia.org/wiki/Small_arms_ammunition...

    The test cartridge must be inserted into the chamber in such a way that the hole in the test cartridge case lines up with a gas port hole that channels the gas pressure from the cartridge case to the face of the sensor. The measurement accuracy of the pressure measurements with 21st century high-pressure sensors is expected to be ≤ 2%. [7]

  8. Hydrostatic test - Wikipedia

    en.wikipedia.org/wiki/Hydrostatic_test

    Hydrostatic tests are conducted under the constraints of either the industry's or the customer's specifications, or may be required by law. The vessel is filled with a nearly incompressible liquid – usually water or oil – pressurised to test pressure, and examined for leaks or permanent changes in shape.

  9. Pressure regulator - Wikipedia

    en.wikipedia.org/wiki/Pressure_regulator

    Diagram symbols for pressure reduction and back pressure regulators. The conceptual difference is mainly in which side the feedback is taken from. A pressure regulator is a valve that controls the pressure of a fluid to a desired value, using negative feedback from the controlled pressure. Regulators are used for gases and liquids, and can be ...