Ralph R. Proctor went on to teach at the University of Arkansas. In 1958, the modified Proctor compaction test was developed as an ASTM standard. A higher and more relevant compaction standard was necessary. There were larger and heavier compaction equipment, like large vibratory compactors and heavier steel-face rollers. This equipment could ...
The most commonly used laboratory test is called the Proctor compaction test and there are two different methods in obtaining the maximum density. They are the standard Proctor and modified Proctor tests; the modified Proctor is more commonly used. For small dams, the standard Proctor may still be the reference. [5]
The standard penetration test (SPT) is an in-situ dynamic penetration test designed to provide information on the geotechnical engineering properties of soil. This test is the most frequently used subsurface exploration drilling test performed worldwide. The test procedure is described in ISO 22476-3, ASTM D1586 [1] and Australian Standards AS ...
The CBR test is a penetration test in which a standard piston, with a diameter of 50 mm (1.969 in), is used to penetrate the soil at a standard rate of 1.25 mm/minute. Although the force increases with the depth of penetration, in most cases, it does not increase as quickly as it does for the standard crushed rock, so the ratio decreases.
The test is normally run at several moisture contents, and the moisture content which requires 25 blows to close the groove is interpolated from the test results. The liquid limit test is defined by ASTM standard test method D 4318. [4] The test method also allows running the test at one moisture content where 20 to 30 blows are required to ...
The R-value of a material is determined when the material is in a state of saturation such that water will be exuded from the compacted test specimen when a 16.8 kN load (2.07 MPa) is applied. Since it is not always possible to prepare a test specimen that will exude water at the specified load, it is necessary to test a series of specimens ...
The liquid limit is determined by measuring the water content for which a groove closes after 25 blows in a standard test. [9] [clarification needed] Alternatively, a fall cone test apparatus may be used to measure the liquid limit. The undrained shear strength of remolded soil at the liquid limit is approximately 2 kPa.
A percolation test (colloquially called a perc test) is a test to determine the water absorption rate of soil (that is, its capacity for percolation) in preparation for the building of a septic drain field (leach field) or infiltration basin. [1] The results of a percolation test are required to design a septic system properly.