When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    Such arrays will evenly balance the polyphase load between the phases of the source system. For example, balanced two-phase power can be obtained from a three-phase network by using two specially constructed transformers, with taps at 50% and 86.6% of the primary voltage.

  3. Load balancing (electrical power) - Wikipedia

    en.wikipedia.org/wiki/Load_balancing_(electrical...

    Electrical substation. Load balancing, load matching, or daily peak demand reserve refers to the use of various techniques by electrical power stations to store excess electrical power during low demand periods for release as demand rises. [1] The aim is for the power supply system to have a load factor of 1.

  4. Power-flow study - Wikipedia

    en.wikipedia.org/wiki/Power-flow_study

    In power engineering, the power-flow study, or load-flow study, is a numerical analysis of the flow of electric power in an interconnected system. A power-flow study usually uses simplified notations such as a one-line diagram and per-unit system, and focuses on various aspects of AC power parameters, such as Voltage, voltage angles, real power and reactive power.

  5. Unbalanced circuit - Wikipedia

    en.wikipedia.org/wiki/Unbalanced_circuit

    Comparison of unbalanced (A) and balanced (B) simple low-pass filters. The figure shows two versions of a simple low-pass filter, unbalanced version (A) and balanced version (B). Both circuits have exactly the same effect as filters, they have the same transfer function. However, on the unbalanced circuit, the bottom pole of the input port is ...

  6. Balun - Wikipedia

    en.wikipedia.org/wiki/Balun

    A balun / ˈ b æ l ʌ n / (from "balanced to unbalanced", originally, but now derived from "balancing unit") [1] is an electrical device that allows balanced and unbalanced lines to be interfaced without disturbing the impedance arrangement of either line. [2] A balun can take many forms and may include devices that also transform impedances ...

  7. CPC theory - Wikipedia

    en.wikipedia.org/wiki/CPC_Theory

    The development of CPC-based power theory by Leszek S. Czarnecki was initiated in 1983 when he challenged the correctness of existing power theories as applied to single-phase linear, time-invariant (LTI) loads with nonsinusoidal voltage, and next, he revealed the existence of a scattered current, and invented a method of reactance compensation.

  8. Load management - Wikipedia

    en.wikipedia.org/wiki/Load_management

    Since electrical energy is a form of energy that cannot be effectively stored in bulk, it must be generated, distributed, and consumed immediately. When the load on a system approaches the maximum generating capacity, network operators must either find additional supplies of energy or find ways to curtail the load, hence load management.

  9. Scott-T transformer - Wikipedia

    en.wikipedia.org/wiki/Scott-T_transformer

    Two-phase motors draw constant power, just as three-phase motors do, so a balanced two-phase load is converted to a balanced three-phase load. However if a two-phase load is not balanced (more power drawn from one phase than the other), no arrangement of transformers (including the Scott-T transformers) can restore balance: Unbalanced current ...