When.com Web Search

  1. Ads

    related to: main breaker tripping problems

Search results

  1. Results From The WOW.Com Content Network
  2. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    An earth-leakage circuit breaker (ELCB) is a safety device used in electrical installations with high Earth impedance to prevent shock. It detects small stray voltages on the metal enclosures of electrical equipment, and interrupts the circuit if a dangerous voltage is detected.

  3. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    A shunt-trip unit appears similar to a normal breaker and the moving actuators are ganged to a normal breaker mechanism to operate together in a similar way, but the shunt trip is a solenoid intended to be operated by an external constant-voltage signal, rather than a current, commonly the local mains voltage or DC. These are often used to cut ...

  4. Arc fault - Wikipedia

    en.wikipedia.org/wiki/Arc_fault

    Two types of wiring protection are standard thermal breakers and arc fault circuit breakers. Thermal breakers require an overload condition long enough that a heating element in the breaker trips the breaker off. In contrast, arc fault circuit breakers use magnetic or other means to detect increases in current draw much more quickly.

  5. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    This AFCI (the circuit breaker with the yellow label) is an older generation AFCI circuit breaker. The current (as of 2013) devices are referred to as "combination type." An arc-fault circuit interrupter ( AFCI ) or arc-fault detection device ( AFDD ) [ 1 ] is a circuit breaker that breaks the circuit when it detects the electric arcs that are ...

  6. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    Overhead power lines are easiest to diagnose since the problem is usually obvious, e.g., a tree has fallen across the line, or a utility pole is broken and the conductors are lying on the ground. Locating faults in a cable system can be done either with the circuit de-energized, or in some cases, with the circuit under power.

  7. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    Automatically closing the breaker after it has tripped and stayed open for a brief amount of time, usually after 1 to 5 seconds, is a standard procedure. [ 5 ] Reclosers are often used as a key component in a smart grid , as they are effectively computer controlled switchgear which can be remotely operated and interrogated using supervisory ...

  8. Power outage - Wikipedia

    en.wikipedia.org/wiki/Power_outage

    It is the most severe form of power outage that can occur. Blackouts which result from or result in power stations tripping are particularly difficult to recover from quickly. Outages may last from a few minutes to a few weeks depending on the nature of the blackout and the configuration of the electrical network.

  9. Sulfur hexafluoride circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Sulfur_hexafluoride...

    Sulfur hexafluoride circuit breakers protect electrical power stations and distribution systems by interrupting electric currents, when tripped by a protective relay. Instead of oil, air, or a vacuum, a sulfur hexafluoride circuit breaker uses sulfur hexafluoride (SF 6) gas to cool and quench the arc on opening a circuit. Advantages over other ...