When.com Web Search

  1. Ad

    related to: mcquay air cooled chiller parts diagram

Search results

  1. Results From The WOW.Com Content Network
  2. Daikin Applied Americas - Wikipedia

    en.wikipedia.org/wiki/Daikin_Applied_Americas

    During 1941 to 1945, McQuay manufacturing facilities were converted to support the U.S. war effort. McQuay designed and manufactured self-sealing fuel tanks and extended bomb release shackles for the Doolittle Tokyo Raider's B-25s. In the later 1940s and 1950s, McQuay products and sales grew as the demand for commercial air conditioning increased.

  3. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.

  4. Vapor-compression refrigeration - Wikipedia

    en.wikipedia.org/wiki/Vapor-compression...

    A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.

  5. Chiller - Wikipedia

    en.wikipedia.org/wiki/Chiller

    A liquid (glycol based) chiller with an air cooled condenser on the rooftop of a medium size commercial building. In air conditioning systems, chilled coolant, usually chilled water mixed with ethylene glycol, from a chiller in an air conditioning or cooling plant is typically distributed to heat exchangers, or coils, in air handlers or other types of terminal devices which cool the air in ...

  6. Free cooling - Wikipedia

    en.wikipedia.org/wiki/Free_cooling

    The percentage of free cooling achieved mid-season is dependent on seasonal temperatures although partial free cooling commences when the ambient air temperature is 1 °C below the process return water temperature. The water is partially cooled through the free cooler, then flows through the chillers to achieve the required set point temperature.

  7. Cooling tower - Wikipedia

    en.wikipedia.org/wiki/Cooling_tower

    Liquid-cooled chillers are normally more energy efficient than air-cooled chillers due to heat rejection to tower water at or near wet-bulb temperatures. Air-cooled chillers must reject heat at the higher dry-bulb temperature, and thus have a lower average reverse–Carnot-cycle effectiveness. In hot climates, large office buildings, hospitals ...

  8. Piping and instrumentation diagram - Wikipedia

    en.wikipedia.org/wiki/Piping_and_instrumentation...

    Piping and instrumentation diagram of pump with storage tank. Symbols according to EN ISO 10628 and EN 62424. A more complex example of a P&ID. A piping and instrumentation diagram (P&ID) is defined as follows: A diagram which shows the interconnection of process equipment and the instrumentation used to control the process.

  9. Chiller boiler system - Wikipedia

    en.wikipedia.org/wiki/Chiller_boiler_system

    A chiller boiler system is a hydronic system. It uses water instead of air to heat and cool a structure. A properly designed hydronic system is usually more efficient than a standard forced air system. [1] Chiller boiler systems use radiant heating and cooling or fan coil systems to condition a home or business. This allows for multiple zones ...

  1. Ad

    related to: mcquay air cooled chiller parts diagram