A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
An example of a Levey–Jennings chart with upper and lower limits of one and two times the standard deviation. A Levey–Jennings chart is a graph that quality control data is plotted on to give a visual indication whether a laboratory test is working well.
A check should first be done to ensure that the data should be seen is precise and accurate. Next, systematic daily checks such as analysing blanks, calibration standards, quality control check samples, and references must be performed to establish the reproducibility of the data.
A blank solution is a solution containing little to no analyte of interest, [1] usually used to calibrate instruments such as a colorimeter. According to the EPA, the "primary purpose of blanks is to trace sources of artificially introduced contamination." [2] Different types of blanks are used to identify the source of contamination in the ...
Reference materials are particularly important for analytical chemistry and clinical analysis. [2] Since most analytical instrumentation is comparative, it requires a sample of known composition (reference material) for accurate calibration.
Calibration is needed because the glass electrode does not give reproducible electrostatic potentials over longer periods of time. [13]: 238–239 Consistent with principles of good laboratory practice, calibration is performed with at least two standard buffer solutions that span the range of pH values to be measured. For general purposes ...
Using the calibration curve method, the analyst can calibrate the spectrometer with a pure silver aqueous solutions, and use the calibration graph to determine the amount of silver present in the waste samples. This method, however, assumes the pure aqueous solution of silver and a photographic waste sample have the same matrix and therefore ...