When.com Web Search

  1. Ad

    related to: why would gfci breaker trip rating chart for rv water heater anode rod aluminum vs magnesium

Search results

  1. Results From The WOW.Com Content Network
  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  3. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    An earth-leakage circuit breaker (ELCB) is a safety device used in electrical installations to prevent shock. It consists of either a current sensing mechanism, or a voltage sensing mechanism. Such a protection mechanism may be found in the form of distribution board modules, standalone devices, and special sockets (aka receptacles ).

  4. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    Circuit breakers with higher ratings can have adjustable trip settings, allowing fewer standardized products to be used, adjusted to the applicable precise ratings when installed. For example, a circuit breaker with a 400 ampere frame size might have its over-current detection threshold set only 300 amperes where that rating is appropriate.

  5. Cathodic protection - Wikipedia

    en.wikipedia.org/wiki/Cathodic_protection

    Aluminum sacrificial anodes (light colored rectangular bars) mounted on a steel jacket structure. Zinc sacrificial anode (rounded object) screwed to the underside of the hull of a small boat. Cathodic protection (CP; / k æ ˈ θ ɒ d ɪ k / ⓘ) is a technique used to control the corrosion of a metal surface by making it the cathode of an ...

  6. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    This AFCI (the circuit breaker with the yellow label) is an older generation AFCI circuit breaker. The current (as of 2013) devices are referred to as "combination type." An arc-fault circuit interrupter ( AFCI ) or arc-fault detection device ( AFDD ) [ 1 ] is a circuit breaker that breaks the circuit when it detects the electric arcs that are ...

  7. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    Types used in commercial and industrial low-voltage distribution systems are rated to safely interrupt 200,000 amperes. The rating of power circuit breakers varies according to the application voltage; a circuit breaker that interrupts 50,000 amperes at 208 volts might be rated to interrupt only 10,000 amperes at 600 volts, for example.

  8. Galvanic anode - Wikipedia

    en.wikipedia.org/wiki/Galvanic_anode

    An aluminum-zinc-tin alloy called KA90 is commonly used in marine and water heater applications. [9] Zinc and aluminium are generally used in salt water, where the resistivity is generally lower and magnesium dissolves relatively quickly by reaction with water under hydrogen evolution (self-corrosion).

  9. Transient recovery voltage - Wikipedia

    en.wikipedia.org/wiki/Transient_Recovery_Voltage

    Examples of TRV waveshapes. A transient recovery voltage (TRV) for high-voltage circuit breakers is the voltage that appears across the terminals after current interruption. It is a critical parameter for fault interruption by a high-voltage circuit breaker, its characteristics (amplitude, rate of rise) can lead either to a successful current interruption or to a failure (called reignition or ...