When.com Web Search

  1. Ads

    related to: backflow valve cover sprinkler replacement video instructions

Search results

  1. Results From The WOW.Com Content Network
  2. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.

  3. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices , [ 1 ] [ 2 ] reduced pressure zone assemblies (RPZA), [ 3 ] or reduced pressure ...

  4. Atmospheric vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Atmospheric_vacuum_breaker

    Inside this elbow is a poppet valve that is held "up" by the water pressure found in the system, closing the air entrance to the device. If the pressure in the "upstream side" is reduced to atmospheric pressure or below, the poppet valve drops and allows air to enter the system, breaking the siphon. [1]

  5. Double check valve - Wikipedia

    en.wikipedia.org/wiki/Double_check_valve

    A double check valve or double check assembly (DCA) is a backflow prevention device designed to protect water supplies from contamination. [1] It is different from the two-way check valves (sometimes erroneously referred to as double check valves) used in air brake systems on heavy trucks which select from the highest pressure source.

  6. Backflow - Wikipedia

    en.wikipedia.org/wiki/Backflow

    A recent introduction to the UK has been the Reduced Pressure Zone (RPZ) valve, a form of double check valve where the intervening zone is drained and normally kept empty. [1] If the downstream valve leaks and permits backflow, this will drain out through the vent rather than building up pressure against the upstream valve.

  7. Plumbing - Wikipedia

    en.wikipedia.org/wiki/Plumbing

    For instance, 1/2" PeX tubing is the same size as 1/2" copper tubing. 1/2" PVC on the other hand is not the same size as 1/2" tubing, and therefore requires either a threaded male or female adapter to connect them. When used in agricultural irrigation, the singular form "pipe" is often used as a plural. [27]