A fire alarm control panel Fire alarm speaker and pull station. Fire alarm systems are composed of several distinct parts: Fire alarm control panel (FACP), or fire alarm control unit (FACU): This component, the hub of the system, monitors inputs and system integrity, controls outputs, and transmits information.
Many modern fire alarm pull stations are single-action and only require the user to pull down a handle to sound the alarm. Other fire alarm pull stations are dual-action, and as such require the user to perform a second task before pulling down, such as lifting or pushing in a panel on the station or breaking a glass panel with an attached hammer.
BS 5839 Part 1 Fire detection and fire alarm systems for buildings – Part 1: Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises [1] is a standard published by the British Standards Institution.
Coded panels were the earliest type of central fire alarm control, and were made during the 1800s to the 1970s. A coded panel is similar in many ways to a modern conventional panel (described below), except each zone was connected to its own code wheel, which, depending on the way the panel was set up, would either do sets of four rounds of code until the initiating pull station was reset ...
Part 14: Guidelines for planning, design, installation, commissioning, use and maintenance (of fire detection and fire alarm systems) 2018-10 No Control panels and power supply EN 54-16 Part 16: Voice alarm control and indicating equipment 2008 Yes Other devices EN 54-17 Part 17: Short circuit isolators 2005 + AC:2007 Yes Other devices EN 54-18
The NFPA 72 "covers the application, installation, location, performance, inspection, testing, and maintenance of fire alarm systems, supervising station alarm systems, public emergency alarm reporting systems, fire warning equipment and emergency communications systems (ECS), and their components."
The alarm transmission methods covered under UL 365 can be categorized under standard line security or encrypted line security. The systems are required to operate within the limits of Class 2 remote control and signal circuits as defined by the National Electrical Code, NFPA 70.
An aspirating smoke detector (ASD) is a system used in active fire protection, consisting of a central detection unit which draws air through a network of pipes to detect smoke. [1] The sampling chamber is based on a nephelometer that detects the presence of smoke particles suspended in air by detecting the light scattered by them in the chamber.