When.com Web Search

  1. Ads

    related to: replacement lens for fluorescent 2x4 microscope

Search results

  1. Results From The WOW.Com Content Network
  2. Fluorescence microscope - Wikipedia

    en.wikipedia.org/wiki/Fluorescence_microscope

    The quest for fluorescent probes with a high specificity that also allow live imaging of plant cells is ongoing. [7] There are many fluorescent molecules called fluorophores or fluorochromes such as fluorescein, Alexa Fluors, or DyLight 488, which can be chemically linked to a different molecule which binds the target of interest within the sample.

  3. Objective (optics) - Wikipedia

    en.wikipedia.org/wiki/Objective_(optics)

    Two Leica oil immersion microscope objective lenses; left 100×, right 40×. The objective lens of a microscope is the one at the bottom near the sample. At its simplest, it is a very high-powered magnifying glass, with very short focal length. This is brought very close to the specimen being examined so that the light from the specimen comes ...

  4. Condenser (optics) - Wikipedia

    en.wikipedia.org/wiki/Condenser_(optics)

    As with objective lenses, a condenser lens with a maximum numerical aperture of greater than 0.95 is designed to be used under oil immersion (or, more rarely, under water immersion), with a layer of immersion oil placed in contact with both the slide/coverslip and the lens of the condenser. An oil immersion condenser may typically have NA of up ...

  5. Köhler illumination - Wikipedia

    en.wikipedia.org/wiki/Köhler_illumination

    Köhler illumination is a method of specimen illumination used for transmitted and reflected light (trans- and epi-illuminated) optical microscopy.Köhler illumination acts to generate an even illumination of the sample and ensures that an image of the illumination source (for example a halogen lamp filament) is not visible in the resulting image.

  6. Oil immersion - Wikipedia

    en.wikipedia.org/wiki/Oil_immersion

    The refractive indices of the oil and of the glass in the first lens element are nearly the same, which means that the refraction of light will be small upon entering the lens (the oil and glass are optically very similar). The correct immersion oil for an objective lens has to be used to ensure that the refractive indices match closely. Use of ...

  7. Total internal reflection fluorescence microscope - Wikipedia

    en.wikipedia.org/wiki/Total_internal_reflection...

    A total internal reflection fluorescence microscope (TIRFM) is a type of microscope with which a thin region of a specimen, usually less than 200 nanometers can be observed. TIRFM is an imaging modality which uses the excitation of fluorescent cells in a thin optical specimen section that is supported on a glass slide.

  1. Ad

    related to: replacement lens for fluorescent 2x4 microscope