When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Reference designator - Wikipedia

    en.wikipedia.org/wiki/Reference_designator

    Separable assembly or sub-assembly (e.g. printed circuit assembly) AT: Attenuator or isolator: BR: Bridge rectifier (four diodes in a package) often changed to "D" for diode BT, BAT: Battery or battery holder: often shortened to "B" C: Capacitor: CB: Circuit breaker: CN: Capacitor network: may be simplified to "C" for capacitor D, CR: Diode ...

  3. ANSI device numbers - Wikipedia

    en.wikipedia.org/wiki/ANSI_device_numbers

    In electric power systems and industrial automation, ANSI Device Numbers can be used to identify equipment and devices in a system such as relays, circuit breakers, or instruments. The device numbers are enumerated in ANSI / IEEE Standard C37.2 Standard for Electrical Power System Device Function Numbers, Acronyms, and Contact Designations .

  4. Circuit breaker design pattern - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker_design_pattern

    The Circuit Breaker is a design pattern commonly used in software development to improve system resilience and fault tolerance. Circuit breaker pattern can prevent cascading failures particularly in distributed systems. [1] In distributed systems, the Circuit Breaker pattern can be used to monitor service health and can detect failures dynamically.

  5. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    During those 1.5 cycles, other separate circuits can see voltage dips or blinks until the affected circuit opens to stop the fault current. Automatically closing the breaker after it has tripped and stayed open for a brief amount of time, usually after 1 to 5 seconds, is a standard procedure. [5]

  6. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    A small circuit breaker typically has a manual control lever to switch the circuit off or reset a tripped breaker, while a larger unit may use a solenoid to trip the mechanism, and an electric motor to restore energy to springs (which rapidly separate contacts when the breaker is tripped).

  7. Distribution board - Wikipedia

    en.wikipedia.org/wiki/Distribution_board

    A distribution board (also known as panelboard, circuit breaker panel, breaker panel, electric panel, fuse box or DB box) is a component of an electricity supply system that divides an electrical power feed into subsidiary circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure.

  8. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or ...

  9. Computer-based interlocking - Wikipedia

    en.wikipedia.org/wiki/Computer-based_interlocking

    When interfacing different brands of CBI equipment, it may be necessary to use relays of each regime, which are then hardwired from one to the other. This happens in the middle of the Channel Tunnel where French and British signalling equipment meet.