When.com Web Search

  1. Ad

    related to: what is selenography in blood pressure monitor error codes

Search results

  1. Results From The WOW.Com Content Network
  2. Sphygmomanometer - Wikipedia

    en.wikipedia.org/wiki/Sphygmomanometer

    A sphygmomanometer (/ ˌ s f ɪ ɡ m oʊ m ə ˈ n ɒ m ɪ t ə r / SFIG-moh-mə-NO-mi-tər), also known as a blood pressure monitor, or blood pressure gauge, is a device used to measure blood pressure, composed of an inflatable cuff to collapse and then release the artery under the cuff in a controlled manner, [1] and a mercury or aneroid manometer to measure the pressure.

  3. Auscultatory gap - Wikipedia

    en.wikipedia.org/wiki/Auscultatory_gap

    Typically, the blood pressure obtained via palpation is around 10 mmHg lower than the pressure obtained via auscultation. In general, the examiner can avoid being confused by an auscultatory gap by always inflating a blood pressure cuff to 20-40 mmHg higher than the pressure required to occlude the brachial pulse .

  4. Blood pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Blood_pressure_measurement

    A minimum systolic value can be roughly estimated by palpation, most often used in emergency situations, but should be used with caution. [10] It has been estimated that, using 50% percentiles, carotid, femoral and radial pulses are present in patients with a systolic blood pressure > 70 mmHg, carotid and femoral pulses alone in patients with systolic blood pressure of > 50 mmHg, and only a ...

  5. Continuous noninvasive arterial pressure - Wikipedia

    en.wikipedia.org/wiki/Continuous_noninvasive...

    When the heart ejects stroke volume to the arteries, it takes a certain transit time until the blood pressure wave arrives in the periphery. This pulse transit time (PTT) indirectly depends on blood pressure – the higher the pressure, the faster PTT. This circumstance can be used for the noninvasive detection of blood pressure changes.

  6. Non-invasive measurement of intracranial pressure - Wikipedia

    en.wikipedia.org/wiki/Non-invasive_measurement...

    Externally applied pressure is equal to systolic blood pressure in this case. The examiner slowly releases the air from the cuff and uses a stethoscope to listen for the return of blood flow. At the pressure balance point, where the pressure in the cuff equals systolic artery pressure, a ‘whooshing’ noise can be heard as blood flows through ...

  7. Ambulatory blood pressure - Wikipedia

    en.wikipedia.org/wiki/Ambulatory_blood_pressure

    Ambulatory blood pressure monitoring allows blood pressure to be intermittently monitored during sleep and is useful to determine whether the patient is a "dipper" or "non-dipper"—that is to say, whether or not blood pressure falls at night compared to daytime values. A nighttime fall is normal and desirable.

  8. Korotkoff sounds - Wikipedia

    en.wikipedia.org/wiki/Korotkoff_sounds

    If the pressure is dropped to a level equal to that of the patient's systolic blood pressure, the first Korotkoff sound will be heard. As the pressure in the cuff is the same as the pressure produced by the heart, some blood will be able to pass through the upper arm when the pressure in the artery rises during systole.

  9. Mean arterial pressure - Wikipedia

    en.wikipedia.org/wiki/Mean_arterial_pressure

    Mean arterial pressure in relation to systolic and diastolic pressure in blood vessels. While MAP can only be measured directly by invasive monitoring, it can be estimated by using a formula in which the lower (diastolic) blood pressure is doubled and added to the higher (systolic) blood pressure and that composite sum then is divided by 3 to estimate MAP.