    The lower the return temperature to the boiler the more likely it will be in condensing mode. If the return temperature is kept below approximately 55 °C (131 °F), the boiler should still be in condensing mode making low temperature applications such as radiant floors and even old cast iron radiators a good match for the technology.

  3. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    At least one combination over-temperature and over-pressure relief valve is always fitted to the system to allow the steam or water to vent to the atmosphere in case of the failure of some mechanism (such as the boiler temperature control) rather than allowing the catastrophic bursting of the piping, radiators, or boiler. The relief valve ...

  4. Boiler feedwater - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater

    Extreme boiler scale buildup Limescale buildup inside a pipe both reduces liquid flow through the pipe, as well as reduces thermal conduction from the liquid to the outer pipe shell. Both effects will reduce the pipe's overall thermal efficiency when used as a heat exchanger. Boiler feedwater is the water which is supplied to a boiler.

  5. Boiler design - Wikipedia

    en.wikipedia.org/wiki/Boiler_design

    Boiler design is the process of designing boilers used for various purposes. The main function of a boiler is to heat water to generate steam. Steam produced in a boiler can be used for a variety of purposes including space heating, sterilisation, drying, humidification and power generation. The temperature or condition of steam required for ...

  6. Boiler - Wikipedia

    en.wikipedia.org/wiki/Boiler

    To measure the boiler efficiency in indirect method, parameter like these are needed: Ultimate analysis of fuel (H 2, S 2, S, C, moisture constraint, ash constraint) Percentage of O 2 or CO 2 at flue gas; Flue gas temperature at outlet; Ambient temperature in °C and humidity of air in kg/kg; GCV of fuel in kcal/kg; Ash percentage in ...

  7. OpenTherm - Wikipedia

    en.wikipedia.org/wiki/OpenTherm

    OpenTherm (OT) is a standard communications protocol used in central heating systems for the communication between central heating appliances and a thermostatic controllers. [1] As a standard, OpenTherm is independent of any single manufacturer. A controller from one manufacturer can in principle be used to control a boiler from another ...