When.com Web Search

  1. Ad

    related to: how to size a transformer kva to btu chart for rv generator

Search results

  1. Results From The WOW.Com Content Network
  2. Power plant efficiency - Wikipedia

    en.wikipedia.org/wiki/Power_plant_efficiency

    This thermal energy input of 1 kWh = 3.6 MJ = 3,412 Btu; Therefore, the heat rate of a 100% efficient plant is simply 1, or 1 kWh/kWh, or 3.6 MJ/kWh, or 3,412 Btu/kWh; To express the efficiency of a generator or power plant as a percentage, invert the value if dimensionless notation or same unit are used. For example:

  3. Load bank - Wikipedia

    en.wikipedia.org/wiki/Load_bank

    That is, for each kilowatt (or horsepower) of load applied to the generator by the load bank, an equal amount of load is applied to the prime mover by the generator. A resistive load bank, therefore, removes energy from the complete system: load bank from generatorgenerator from prime mover—prime mover from fuel.

  4. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    Closer to the customer, a distribution transformer steps the primary distribution power down to a low-voltage secondary circuit, usually 120/240 V in the US for residential customers. The power comes to the customer via a service drop and an electricity meter. The final circuit in an urban system may be less than 15 metres (50 ft) but may be ...

  5. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    Due to high cost of a generator, a set of sensors and limiters will trigger the alarm when the generator approaches the capability-set boundary and, if no action is taken by the operator, will disconnect the generator from the grid. [3] D-curve expands with cooling. The D-curve for a particular generator can be expanded by improved cooling.

  6. Rotary converter - Wikipedia

    en.wikipedia.org/wiki/Rotary_converter

    1909 500 kW Westinghouse rotary converter. A rotary converter is a type of electrical machine which acts as a mechanical rectifier, inverter or frequency converter.. Rotary converters were used to convert alternating current (AC) to direct current (DC), or DC to AC power, before the advent of chemical or solid state power rectification and inverting.

  7. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    A "transformer bank", widely used in North America: three single-phase transformers connected to make a 3-phase transformer. The low-voltage secondary windings are attached to three or four terminals on the transformer's side. In North American residences and small businesses, the secondary is often the split-phase 120/240-volt system. The 240 ...

  8. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    A planar transformer Exploded view: the spiral primary "winding" on one side of the PCB (the spiral secondary "winding" is on the other side of the PCB) Manufacturers either use flat copper sheets or etch spiral patterns on a printed circuit board to form the "windings" of a planar transformer, replacing the turns of wire used to make other ...

  9. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    A transformer supplying a three-wire distribution system has a single-phase input (primary) winding. The output (secondary) winding has a center tap connected to a grounded neutral. As shown in Fig. 1, either end to center has half the voltage of end-to-end. Fig. 2 illustrates the phasor diagram