The pads are then attached to a monitor/defibrillator, a heart rate is selected, and current (measured in milliamps) is increased until electrical capture (characterized by a wide QRS complex with tall, broad T wave on the ECG) is obtained, with a corresponding pulse. Pacing artifact on the ECG and severe muscle twitching may make this ...
The difference between pacemakers and ICDs is that pacemakers are also available as temporary units and are generally designed to correct slow heart rates, i.e. bradycardia, while ICDs are often permanent safeguards against sudden life-threatening arrhythmias. S-ICD lead and generator position Sketch of an already-implanted cardioverter ...
Pad placement for electrical cardioversion a cardiac arrhythmia may be either anterior-posterior or anterior-lateral. In an anterior-posterior setup one pad is placed on the chest and the other pad is placed on the back. In an anterior-lateral setup, one pad is placed on the chest and the other pad is placed along the left midaxillary line.
Using X-ray imaging (fluoroscopy), the leads are fed through a vein into the heart and through the heart valve(s) into the heart. Guided by anatomical landmarks and/or an X-ray image, the subcutaneous ICD electrode is tunneled under the skin. The subcutaneous ICD delivers therapy without the need for wires implanted in the heart.
Cardiac resynchronisation therapy (CRT or CRT-P) is the insertion of electrodes in the left and right ventricles of the heart, as well as on occasion the right atrium, to treat heart failure by coordinating the function of the left and right ventricles via a pacemaker, a small device inserted into the anterior chest wall.
The LVAD is the most common device applied to a defective heart (it is sufficient in most cases; the right side of the heart is then often able to make use of the heavily increased blood flow), but when the pulmonary arterial resistance is high, then an (additional) right ventricular assist device (RVAD) might be necessary to resolve the ...
Implantable cardioverter-defibrillators, also known as automatic internal cardiac defibrillator (AICD), are implants similar to pacemakers (and many can also perform the pacemaking function). They constantly monitor the patient's heart rhythm, and automatically administer shocks for various life-threatening arrhythmias, according to the device ...
Percutaneous valve replacement An alternative to open heart surgery, percutaneous valve replacement is the replacement of a heart valve using percutaneous methods. This is performed on the aortic valve (percutaneous aortic valve replacement/TAVI procedure), pulmonary valve and recently the mitral valve Percutaneous valve repair