Ads
related to: why do evaporator coils leak
Search results
Results From The WOW.Com Content Network
An evaporator is a type of heat exchanger device that facilitates evaporation by utilizing conductive and convective heat transfer, which provides the necessary thermal energy for phase transition from liquid to vapour. Within evaporators, a circulating liquid is exposed to an atmospheric or reduced pressure environment causing it to boil at a ...
To complete the refrigeration cycle, the refrigerant vapor from the evaporator is again a saturated vapor and is routed back into the compressor. Over time, the evaporator may collect ice or water from ambient humidity. The ice is melted through defrosting. The water from the melted ice or the evaporator then drips into a drip pan, and the ...
Also, TX valve air conditioning systems do not require an accumulator (a refrigerant tank placed downstream of the evaporator's outlet), since the valves reduce the liquid refrigerant flow when the evaporator's thermal load decreases, so that all the refrigerant completely evaporates inside the evaporator (in normal operating conditions such as ...
For cooling coils, chilled water and refrigerant are most common. Chilled water is supplied from a chiller that is potentially located very far away, but refrigerant must come from a nearby condensing unit. When a refrigerant is used, the cooling coil is the evaporator, and the heating coil is the condenser in the vapor-compression ...
That results in a mixture of liquid and vapour at a lower temperature and pressure as shown at point 5. The cold liquid-vapor mixture then travels through the evaporator coil or tubes and is completely vaporized by cooling the warm air (from the space being refrigerated) being blown by a fan across the evaporator coil or tubes.
A vapor-compression evaporator, like most evaporators, can make reasonably clean water from any water source. In a salt crystallizer, for example, a typical analysis of the resulting condensate shows a typical content of residual salt not higher than 50 ppm or, in terms of electrical conductance , not higher than 10 μS/cm .
The low temperature system removes heat from the space to be cooled using an evaporator, and transfers it to a heat exchanger that is cooled by the evaporation of the refrigerant of the high temperature system. Alternatively, a liquid-to-liquid or similar heat exchanger may be used instead.
Removing of the circulation pump reduces the operating costs, however due to characteristics of the system as mentioned above the evaporator has a long residence time and low flow rates, [11] making its uses severely more limited than a forced circulation evaporator. The most common application of Natural Circulation evaporation is as a ...