When.com Web Search

  1. Ads

    related to: delta 3 way diverter diagram

Search results

  1. Results From The WOW.Com Content Network
  2. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Phasor diagram showing 240 V delta and center-tapped phase (a–c) creating two 120 V pairs. Consider the low-voltage side of a 120/240 V high leg delta connected transformer, where the b phase is the high leg. The line-to-line voltage magnitudes are all the same: = = =.

  3. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    The delta winding allows third-harmonic currents to circulate within the transformer, and prevents third-harmonic currents from flowing in the supply line. [2] Delta-wye transformers introduce a 30, 150, 210, or 330 degree phase shift. [3] Thus they cannot be paralleled with wye-wye (or delta-delta) transformers.

  4. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    A three-phase system may be arranged in delta (∆) or star (Y) (also denoted as wye in some areas, as symbolically it is similar to the letter 'Y'). A wye system allows the use of two different voltages from all three phases , such as a 230/400 V system which provides 230 V between the neutral (centre hub) and any one of the phases, and 400 V ...

  5. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. Three-phase electric power (abbreviated 3ϕ [1]) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. [2]

  6. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Delta – A 'delta' or 'phase to phase' transformer is used on a delta distribution circuit. A single-phase delta transformer has two bushings connected to two of the three primary wires, so the primary winding sees the phase-to-phase voltage; this avoids returning primary current through a neutral that must be solidly grounded to keep its ...

  7. Tap changer - Wikipedia

    en.wikipedia.org/wiki/Tap_changer

    One possible design (flag type) of on load mechanical tap changer is shown in the diagram. It commences operation at tap position 2, with load supplied directly via the connection ont the right. Diverter resistor A is short-circuited; diverter B is unused. In moving to tap 3, the following sequence occurs: Switch 3 closes, an off-load operation.

  8. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    Thus 1 = 30°, 2 = 60°, 3 = 90°, 6 = 180° and 12 = 0° or 360°. According to the IEC60076-1 standard, the notation is HV-LV in sequence. For example, a step-up transformer with a delta-connected primary and a wye-connected secondary is still labeled as 'Yd1'. The 1 indicates the LV winding lags the HV by 30 degrees. [1]

  9. Single-line diagram - Wikipedia

    en.wikipedia.org/wiki/Single-line_diagram

    A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.