When.com Web Search

  1. Ads

    related to: industrial cooling tower design calculation pdf download full version

Search results

  1. Results From The WOW.Com Content Network
  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  3. Cooling tower - Wikipedia

    en.wikipedia.org/wiki/Cooling_tower

    A typical evaporative, forced draft open-loop cooling tower rejecting heat from the condenser water loop of an industrial chiller unit Natural draft wet cooling hyperboloid towers at Didcot Power Station (UK) Forced draft wet cooling towers (height: 34 meters) and natural draft wet cooling tower (height: 122 meters) in Westphalia, Germany Natural draft wet cooling tower in Dresden (Germany)

  4. Hyperboloid structure - Wikipedia

    en.wikipedia.org/wiki/Hyperboloid_structure

    Hence they are more commonly used in purpose-driven structures, such as water towers (to support a large mass), cooling towers, and aesthetic features. [3] A hyperbolic structure is beneficial for cooling towers. At the bottom, the widening of the tower provides a large area for installation of fill to promote thin film evaporative cooling of ...

  5. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  6. Axial fan design - Wikipedia

    en.wikipedia.org/wiki/Axial_fan_design

    Fans have many applications including in wind tunnels and cooling towers. Design parameters include power, flow rate, pressure rise and efficiency. [1] Axial fans generally comprise fewer blades (two to six) than centrifugal fans. Axial fans commonly have larger radius and lower speed (ω) than ducted fans (esp. at similar power.

  7. Mass transfer - Wikipedia

    en.wikipedia.org/wiki/Mass_transfer

    In industrial processes, mass transfer operations include separation of chemical components in distillation columns, absorbers such as scrubbers or stripping, adsorbers such as activated carbon beds, and liquid-liquid extraction. Mass transfer is often coupled to additional transport processes, for instance in industrial cooling towers. These ...

  8. Discover the latest breaking news in the U.S. and around the world — politics, weather, entertainment, lifestyle, finance, sports and much more.

  9. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [1] [2] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs. The COP is used in thermodynamics.