When.com Web Search

  1. Ads

    related to: arterial vs capillary blood glucose normal values range

Search results

  1. Results From The WOW.Com Content Network
  2. Random glucose test - Wikipedia

    en.wikipedia.org/wiki/Random_glucose_test

    The reference values for a "normal" random glucose test in an average adult are 80–140mg/dl (4.4–7.8 mmol/l), between 140 and 200mg/dl (7.8–11.1 mmol/l) is considered pre-diabetes [citation needed], and ≥ 200 mg/dl is considered diabetes according to ADA guidelines [1] (you should visit your doctor or a clinic for additional tests however as a random glucose of > 160mg/dl does not ...

  3. Reference ranges for blood tests - Wikipedia

    en.wikipedia.org/wiki/Reference_ranges_for_blood...

    An exception is for acid–base and blood gases, which are generally given for arterial blood. [citation needed] Still, the blood values are approximately equal between the arterial and venous sides for most substances, with the exception of acid–base, blood gases and drugs (used in therapeutic drug monitoring (TDM) assays). [6]

  4. Blood sugar level - Wikipedia

    en.wikipedia.org/wiki/Blood_sugar_level

    But following meals, capillary and arterial blood glucose levels can be significantly higher than venous levels. Although these differences vary widely, one study found that following the consumption of 50 grams of glucose, "the mean capillary blood glucose concentration is higher than the mean venous blood glucose concentration by 35%." [33] [34]

  5. Glucose test - Wikipedia

    en.wikipedia.org/wiki/Glucose_test

    A level below 5.6 mmol/L (100 mg/dL) 10–16 hours without eating is normal. 5.6–6 mmol/L (100–109 mg/dL) may indicate prediabetes and oral glucose tolerance test (OGTT) should be offered to high-risk individuals (old people, those with high blood pressure etc.). 6.1–6.9 mmol/L (110–125 mg/dL) means OGTT should be offered even if other ...

  6. Blood glucose monitoring - Wikipedia

    en.wikipedia.org/wiki/Blood_glucose_monitoring

    Blood glucose monitoring is the use of a glucose meter for testing the concentration of glucose in the blood . Particularly important in diabetes management , a blood glucose test is typically performed by piercing the skin (typically, via fingerstick ) to draw blood, then applying the blood to a chemically active disposable 'test-strip'.

  7. Glucose tolerance test - Wikipedia

    en.wikipedia.org/wiki/Glucose_tolerance_test

    The glucose tolerance test was first described in 1923 by Jerome W. Conn. [4]The test was based on the previous work in 1913 by A. T. B. Jacobson in determining that carbohydrate ingestion results in blood glucose fluctuations, [5] and the premise (named the Staub-Traugott Phenomenon after its first observers H. Staub in 1921 and K. Traugott in 1922) that a normal patient fed glucose will ...

  8. Reference range - Wikipedia

    en.wikipedia.org/wiki/Reference_range

    The standard definition of a reference range for a particular measurement is defined as the interval between which 95% of values of a reference population fall into, in such a way that 2.5% of the time a value will be less than the lower limit of this interval, and 2.5% of the time it will be larger than the upper limit of this interval, whatever the distribution of these values.

  9. Insulinoma - Wikipedia

    en.wikipedia.org/wiki/Insulinoma

    During the test, the patient may have calorie-free and caffeine-free liquids. Capillary blood glucose is measured every 4 hours using a reflectance meter, until values < 60 mg/dL (3.3 mmol/L) are obtained. Then, the frequency of blood glucose measurement is increased to every hour until values are < 49 mg/dL (2.7 mmol/L).