When.com Web Search

  1. Ads

    related to: connecting walls only connect to ceiling duct in house design

Search results

  1. Results From The WOW.Com Content Network
  2. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    A form of bus duct known as "plug-in bus" is used to distribute power down the length of a building; it is constructed to allow tap-off switches or motor controllers to be installed at designated places along the bus. The big advantage of this scheme is the ability to remove or add a branch circuit without removing voltage from the whole duct.

  3. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Ducts for air pollution control in a 17000 standard cubic feet per minute regenerative thermal oxidizer (RTO). A round galvanized steel duct connecting to a typical diffuser Fire-resistance rated mechanical shaft with HVAC sheet metal ducting and copper piping, as well as "HOW" (Head-Of-Wall) joint between top of concrete block wall and underside of concrete slab, firestopped with ceramic ...

  4. Breezeway - Wikipedia

    en.wikipedia.org/wiki/Breezeway

    A breezeway is an architectural feature similar to a hallway that allows the passage of a breeze between structures to accommodate high winds, allow aeration, or provide aesthetic design variation. Often, a breezeway is a simple roof connecting two structures (such as a house and a garage); sometimes, it can be much more like a tunnel with ...

  5. Electrical conduit - Wikipedia

    en.wikipedia.org/wiki/Electrical_conduit

    A duct bank will allow replacement of damaged cables between buildings or additional power and communications circuits to be added, without the expense of re-excavation of a trench. While metal conduit is occasionally used for burial, usually PVC , polyethylene or polystyrene plastics are now used due to lower cost, easier installation, and ...

  6. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    In a UFAD design, conditioned air stays in the lower, occupied part of the room, while heat sources such as occupants and equipment generate thermal plumes, which carry the warm air and heat source generated pollutants towards the ceiling where they are exhausted through the return air ducts. [8]

  7. Register (air and heating) - Wikipedia

    en.wikipedia.org/wiki/Register_(air_and_heating)

    An unlouvered wall register, which allows circulation of air from one floor to another. Registers vary in size with the heating and cooling requirements of the room. [5] If a register is too small, the HVAC system will need to push air through the ducts at a faster rate in order to achieve the desired heating or cooling.

  8. Curtain wall (architecture) - Wikipedia

    en.wikipedia.org/wiki/Curtain_wall_(architecture)

    The extensive glass walls allowed light to penetrate further into the building, utilizing more floor space and reducing lighting costs. Oriel Chambers comprises 43,000 sq ft (4,000 m 2) set over five floors without an elevator, which had only recently been invented and was not yet widespread. [3]

  9. Glossary of architecture - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_architecture

    Any architectural element's underside, especially the board connecting the walls of a structure to the fascia or the end of the roof, enclosing the eave. Sommer or Summer A girder or main "summer beam" of a floor: if supported on two storey posts and open below, also called a "bress" or "breast-summer".