When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Retardation factor - Wikipedia

    en.wikipedia.org/wiki/Retardation_factor

    An R F value will always be in the range 0 to 1; if the substance moves, it can only move in the direction of the solvent flow, and cannot move faster than the solvent. For example, if particular substance in an unknown mixture travels 2.5 cm and the solvent front travels 5.0 cm, the retardation factor would be 0.50.

  3. Response factor - Wikipedia

    en.wikipedia.org/wiki/Response_factor

    The response factor can be expressed on a molar, volume or mass [1] basis. Where the true amount of sample and standard are equal: = where A is the signal (e.g. peak area) and the subscript i indicates the sample and the subscript st indicates the standard. [2]

  4. Chromatographic response function - Wikipedia

    en.wikipedia.org/wiki/Chromatographic_response...

    They are the smallest difference between sorted RF values, or product of such differences. Another function is the multispot response function (MRF) as developed by De Spiegeleer et al.{Analytical Chemistry (1987):59(1),62-64} It is based also of differences product. This function always lies between 0 and 1.

  5. Effective radiated power - Wikipedia

    en.wikipedia.org/wiki/Effective_radiated_power

    Horizontal is the standard for both, but if the vertical ERP is larger it will be used instead. The maximum ERP for US FM broadcasting is usually 100,000 watts (FM Zone II) or 50,000 watts (in the generally more densely populated Zones I and I-A), though exact restrictions vary depending on the class of license and the antenna height above ...

  6. List of common EMC test standards - Wikipedia

    en.wikipedia.org/wiki/List_of_common_EMC_test...

    CISPR is the acronym of Comité International Spécial des Perturbations Radio, [1] or the International Special Committee for Radio Protection of IEC. CISPR Standards aim to the protection of radio reception in the range 9 kHz to 400 GHz from interference caused by operation of electrical or electronic appliances and systems in the electromagnetic environment.

  7. Specific absorption rate - Wikipedia

    en.wikipedia.org/wiki/Specific_absorption_rate

    Specific absorption rate (SAR) is a measure of the rate at which energy is absorbed per unit mass by a human body when exposed to a radio frequency (RF) electromagnetic field. It is defined as the power absorbed per mass of tissue and has units of watts per kilogram (W/kg).

  8. Standard normal table - Wikipedia

    en.wikipedia.org/wiki/Standard_normal_table

    Example: To find 0.69, one would look down the rows to find 0.6 and then across the columns to 0.09 which would yield a probability of 0.25490 for a cumulative from mean table or 0.75490 from a cumulative table. To find a negative value such as -0.83, one could use a cumulative table for negative z-values [3] which yield a probability of 0.20327.

  9. Received signal strength indicator - Wikipedia

    en.wikipedia.org/wiki/Received_signal_strength...

    RSSI is an indication of the power level being received by the receiving radio after the antenna and possible cable loss. Therefore, the greater the RSSI value, the stronger the signal. Thus, when an RSSI value is represented in a negative form (e.g. −100), the closer the value is to 0, the stronger the received signal has been.