When.com Web Search

  1. Ads

    related to: air vent valve for water heater

Search results

  1. Results From The WOW.Com Content Network
  2. Automatic bleeding valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_bleeding_valve

    A dry valve acts as an air vent until a dribble of water passes through it and swells the cartridge. If the valve dries out again, it re-opens. A characteristic of these valves is that they function best on the hot delivery side of a radiator and may not open as vents unless the water supply is hot. [8]

  3. Drain-waste-vent system - Wikipedia

    en.wikipedia.org/wiki/Drain-waste-vent_system

    Air admittance valves (AAVs, or commonly referred to in the UK as Durgo valves and in the US as Studor vents and Sure-Vent®) are negative-pressure-activated, one-way mechanical valves, used in a plumbing or drainage venting system to eliminate the need for conventional pipe venting and roof penetrations.

  4. Vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Vacuum_breaker

    Pressure type vacuum breakers are similar to atmospheric vacuum breakers but have a spring-loaded check valve to allow operation of under pressure for long periods of time. Spill-resistant vacuum breakers utilize a check valve and air vent inlet that allows air to enter before the internal check valve opens, thereby preventing water spillage ...

  5. Atmospheric vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Atmospheric_vacuum_breaker

    It is usually constructed of brass and resembles a 90-degree elbow with a hood on its top to allow air to enter the water system if a siphon attempts to form. Inside this elbow is a poppet valve that is held "up" by the water pressure found in the system, closing the air entrance to the device. If the pressure in the "upstream side" is reduced ...

  6. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Most modern hot water boiler heating systems have a circulator, which is a pump, to move hot water through the distribution system (as opposed to older gravity-fed systems). The heat can be transferred to the surrounding air using radiators, hot water coils (hydro-air), or other heat exchangers. The radiators may be mounted on walls or ...

  7. Water heating - Wikipedia

    en.wikipedia.org/wiki/Water_heating

    A tempering valve mixes enough cold water with the hot water from the heater to keep the outgoing water temperature fixed at a more moderate temperature, often set to 50 °C (122 °F). Without a tempering valve, reduction of the water heater's setpoint temperature is the most direct way to reduce scalding.

  8. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    The air exits the system through the air-venting valves on the radiators and on the steam pipes themselves. The thermostatic valves close when they become hot; in the most common kind, the vapor pressure of a small amount of alcohol in the valve exerts the force to actuate the valve and prevent steam from leaving the radiator.

  9. Central heating - Wikipedia

    en.wikipedia.org/wiki/Central_heating

    The condensate water returns to the boiler either by gravity or with the assistance of a pump. Some systems use only a single pipe for combined steam and condensate return. Since trapped air prevents proper circulation, such systems have vent valves to allow air to be purged.