When.com Web Search

  1. Ads

    related to: recommended roof insulation thickness

Search results

  1. Results From The WOW.Com Content Network
  2. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    Installed faced fiberglass batt insulation with its R-value visible (R-21) [1]. The R-value is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3]

  3. List of insulation materials - Wikipedia

    en.wikipedia.org/wiki/List_of_insulation_materials

    This is a list of insulation materials used around the world. Typical R-values are given for various materials and structures as approximations based on the average of available figures and are sorted by lowest value. R-value at 1 m gives R-values normalised to a 1 metre (3 ft 3 in) thickness and sorts by median value of the range.

  4. Structural insulated panel - Wikipedia

    en.wikipedia.org/wiki/Structural_insulated_panel

    EPS is the most common of the foams used and has an R-value (thermal resistance) of about 4 °F·ft 2 ·h/Btu (equivalent to about 0.7 K·m 2 /W) per 25 mm thickness, which would give the 3.5 inches (89 mm) of foam in a 4.5-inch-thick (110 mm) panel an R value of 13.8 (caution: extrapolating R-values over thickness may be imprecise due to non ...

  5. Building insulation material - Wikipedia

    en.wikipedia.org/wiki/Building_insulation_material

    Rigid panel insulation, also known as continuous insulation [13] can be made from foam plastics such as polyisocyanurate or polystyrene, or from fibrous materials such as fiberglass, rock and slag wool. Rigid panel continuous insulation is often used to provide a thermal break in the building envelope, thus reducing thermal bridging.

  6. Dynamic insulation - Wikipedia

    en.wikipedia.org/wiki/Dynamic_insulation

    Dynamic insulation works best with a good thickness of insulation so taking 200 mm of cellulose insulation (k = 0.04 W/m °C) the dynamic U value for an air flow of 0.31 mm/s is calculated using equation above to be 0.066 W/m 2 °C. If a lower dynamic U-value is required then a material with lower air permeability than fibreboard would need to ...

  7. Vacuum insulated panel - Wikipedia

    en.wikipedia.org/wiki/Vacuum_insulated_panel

    This means that VIPs have about one-fifth the thermal conductivity of conventional insulation, and therefore about five times the thermal resistance per unit thickness. Based on a typical k-value of 0.007 W/(m·K), the R-value of a typical 25-millimetre-thick (1 in) VIP would be 3.5 m 2 ·K/W (20 h·ft 2 ·°F/BTU). To provide the same R-value ...