When.com Web Search

  1. Ads

    related to: hvac duct insulation installation guidelines free pdf file

Search results

  1. Results From The WOW.Com Content Network
  2. Sound attenuator - Wikipedia

    en.wikipedia.org/wiki/Sound_attenuator

    A sound attenuator, or duct silencer, sound trap, or muffler, is a noise control acoustical treatment of Heating Ventilating and Air-Conditioning (HVAC) ductwork designed to reduce transmission of noise through the ductwork, either from equipment into occupied spaces in a building, or between occupied spaces. [1] [2]

  3. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Central, "all-air" air-conditioning systems (or package systems) with a combined outdoor condenser/evaporator unit are often installed in North American residences, offices, and public buildings, but are difficult to retrofit (install in a building that was not designed to receive it) because of the bulky air ducts required. [32] (Minisplit ...

  4. Air Movement and Control Association - Wikipedia

    en.wikipedia.org/wiki/Air_Movement_and_Control...

    The Air Movement and Control Association International, Inc. (AMCA) is an international trade body that sets standards for Heating, Ventilation and Air Conditioning equipment. It rates fan balance and vibration, aerodynamic performance, air density, speed and efficiency.

  5. Sheet Metal and Air Conditioning Contractors' National ...

    en.wikipedia.org/wiki/Sheet_Metal_and_Air...

    SMACNA standards and manuals address all facets of the sheet metal industry, from duct construction and installation to indoor air quality and air pollution control, from energy recovery to roofing. SMACNA's Technical Resources Department fields several thousand technical questions annually from architects, engineers, manufacturers and ...

  6. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    While overhead systems typically use ducts to distribute the air, UFAD systems use the underfloor plenum formed by installation of a raised floor. The plenum generally sits 0.3 and 0.46 metres (12 and 18 in) above the structural concrete slab, although lower heights are possible.

  7. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.

  8. Air handler - Wikipedia

    en.wikipedia.org/wiki/Air_handler

    An air handler, or air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning system. [1] An air handler is usually a large metal box containing a blower , furnace or A/C elements, filter racks or chambers, sound attenuators , and dampers . [ 2 ]

  9. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Ducts for air pollution control in a 17000 standard cubic feet per minute regenerative thermal oxidizer (RTO). A round galvanized steel duct connecting to a typical diffuser Fire-resistance rated mechanical shaft with HVAC sheet metal ducting and copper piping, as well as "HOW" (Head-Of-Wall) joint between top of concrete block wall and underside of concrete slab, firestopped with ceramic ...