Search results
Results From The WOW.Com Content Network
A reagent, termed the titrant or titrator, [2] is prepared as a standard solution of known concentration and volume. The titrant reacts with a solution of analyte (which may also be termed the titrand [3]) to determine the analyte's concentration. The volume of titrant that reacted with the analyte is termed the titration volume.
Titration is a family of techniques used to determine the concentration of an analyte. [8] Titrating accurately to either the half-equivalence point or the endpoint of a titration allows the chemist to determine the amount of moles used, which can then be used to determine a concentration or composition of the titrant.
Differences in the temperature between the titrant and the titrand; Evaporative losses from the surface of the rapidly mixed fluid; Heats of solution when the titrant solvent is mixed with the analyte solvent; Heat introduced by the mechanical action of stirring (minor influence); and; Heat produced by the thermistor itself (very minor influence).
This decreased the osmotic pressure of mercury (I) ions on the side and creates a potential difference. This potential difference increases slowly as additional potassium chloride is added, but then increases more rapidly. He found the greatest potential difference is achieved once all of the mercurous nitrate has been precipitated.
A Gran plot (also known as Gran titration or the Gran method) is a common means of standardizing a titrate or titrant by estimating the equivalence volume or end point in a strong acid-strong base titration or in a potentiometric titration.
Finally, the ionization products MH + (H 2 O) m transfer out from the atmospheric-pressure ion source. Declustering (removal of water molecules from the protonated analyte molecule) of MH + (H 2 O) m takes place at the high vacuum of the mass analyzer. [2] The analyte molecule ions detected by MS are [M+H] +. The chemical reactions of ...
Because many definitions of standard temperature and pressure differ in temperature significantly from standard laboratory temperatures (e.g. 0 °C vs. ~28 °C), reference is often made to "standard laboratory conditions" (a term deliberately chosen to be different from the term "standard conditions for temperature and pressure", despite its ...
The difference in intensity is directly proportional to the concentration of the analyte in the sample, following the Beer-Lambert law: * **A = εcl**, where: * A is the absorbance measured. * ε is the molar absorptivity (constant specific to the element and wavelength). * c is the concentration of the analyte.