When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Root mean square - Wikipedia

    en.wikipedia.org/wiki/Root_mean_square

    However, for some purposes the RMS current over a longer period is required when calculating transmission power losses. The same principle applies, and (for example) a current of 10 amps used for 12 hours each 24-hour day represents an average current of 5 amps, but an RMS current of 7.07 amps, in the long term.

  3. Form factor (electronics) - Wikipedia

    en.wikipedia.org/wiki/Form_factor_(electronics)

    In electronics and electrical engineering, the form factor of an alternating current waveform (signal) is the ratio of the RMS (root mean square) value to the average value (mathematical mean of absolute values of all points on the waveform). [1] It identifies the ratio of the direct current of equal power relative to the given alternating ...

  4. True RMS converter - Wikipedia

    en.wikipedia.org/wiki/True_RMS_converter

    True RMS provides a more correct value that is proportional to the square root of the average of the square of the curve, and not to the average of the absolute value. For any given waveform , the ratio of these two averages is constant and, as most measurements are made on what are (nominally) sine waves, the correction factor assumes this ...

  5. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Electrical loads consuming alternating current power consume both real power and reactive power. The vector sum of real and reactive power is the complex power, and its magnitude is the apparent power. The presence of reactive power causes the real power to be less than the apparent power, and so, the electric load has a power factor of less ...

  6. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The plotted line represents the variation of instantaneous voltage (or current) with respect to time. This cycle repeats with a frequency that depends on the power system. In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating voltages that are offset in time by one-third of the period ...

  7. Volt-ampere - Wikipedia

    en.wikipedia.org/wiki/Volt-ampere

    For a simple electrical circuit running on direct current, the electrical current and voltage are constant.In that case, the real power (P, measured in watts) is the product of the current (I, measured in amperes) and the voltage from one side of the circuit to the other (V, measured in volts):

  8. Ripple (electrical) - Wikipedia

    en.wikipedia.org/wiki/Ripple_(electrical)

    Various properties of ripple voltage may be important depending on application: the equation of the ripple for Fourier analysis to determine the constituent harmonics; the peak (usually peak-to-peak) value of the voltage; the root mean square (RMS) value of the voltage which is a component of power transmitted; the ripple factor γ, the ratio ...

  9. List of electromagnetism equations - Wikipedia

    en.wikipedia.org/wiki/List_of_electromagnetism...

    Position vector r is a point to calculate the electric field; r′ is a point in the charged object. Contrary to the strong analogy between (classical) gravitation and electrostatics, there are no "centre of charge" or "centre of electrostatic attraction" analogues. [citation needed] Electric transport