When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. General time- and transfer constant analysis - Wikipedia

    en.wikipedia.org/wiki/General_time-_and_transfer...

    Setting a capacitor value to zero corresponds to an open circuit, while a zero-valued inductor is a short circuit. So for calculation of the , all other capacitors are open-circuited and all other inductors are short-circuited. This is the essence of the ZVT method, which reduces to OCT when only capacitors are involved.

  3. Open-circuit time constant method - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_time_constant...

    Then the resistance seen by the test voltage is found using the circuit in the right panel of Figure 1 and is simply V X / I X = R 1. Form the product C 1 R 1. Add these terms. In effect, it is as though each capacitor charges and discharges through the resistance found in the circuit when the other capacitor is an open circuit.

  4. Mesh analysis - Wikipedia

    en.wikipedia.org/wiki/Mesh_analysis

    Figure 1: Essential meshes of the planar circuit labeled 1, 2, and 3. R 1, R 2, R 3, 1/sC, and sL represent the impedance of the resistors, capacitor, and inductor values in the s-domain. V s and I s are the values of the voltage source and current source, respectively. Mesh analysis (or the mesh current method) is a circuit analysis method for ...

  5. RC time constant - Wikipedia

    en.wikipedia.org/wiki/RC_time_constant

    The following formulae use it, assuming a constant voltage applied across the capacitor and resistor in series, to determine the voltage across the capacitor against time: Charging toward applied voltage (initially zero voltage across capacitor, constant V 0 across resistor and capacitor together) V 0 : V ( t ) = V 0 ( 1 − e − t / τ ...

  6. IEC 61000-4-5 - Wikipedia

    en.wikipedia.org/wiki/IEC_61000-4-5

    The surge is defined by the Combination Wave Generator's open-circuit voltage and short-circuit current waveforms, characterized by front time, duration, and peak values. With an open circuit output, the surge voltage is a double exponential pulse in the form of k ( e − α t − e − β t ) {\displaystyle k(e^{-\alpha t}-e^{-\beta t})} .

  7. Small-signal model - Wikipedia

    en.wikipedia.org/wiki/Small-signal_model

    Small-signal modeling is a common analysis technique in electronics engineering used to approximate the behavior of electronic circuits containing nonlinear devices with linear equations. It is applicable to electronic circuits in which the AC signals (i.e., the time-varying currents and voltages in the circuit) are small relative to the DC ...

  8. Parasitic extraction - Wikipedia

    en.wikipedia.org/wiki/Parasitic_extraction

    In electronic design automation, parasitic extraction is the calculation of the parasitic effects in both the designed devices and the required wiring interconnects of an electronic circuit: parasitic capacitances, parasitic resistances and parasitic inductances, commonly called parasitic devices, parasitic components, or simply parasitics.

  9. Capacitor - Wikipedia

    en.wikipedia.org/wiki/Capacitor

    In the short-time limit, if the capacitor starts with a certain voltage V, since the voltage drop on the capacitor is known at this instant, we can replace it with an ideal voltage source of voltage V. Specifically, if V=0 (capacitor is uncharged), the short-time equivalence of a capacitor is a short circuit.