In electrical engineering, isolated-phase bus (IPB), also known as phase-isolated bus (PIB) in some countries, is a method of construction for circuits carrying very large currents, typically between a generator and its step-up transformer in a steam or large hydroelectric power plant. Isolated phase bus during installation at the Bui Dam Ghana ...
For very large currents in generating stations or substations, where it is difficult to provide circuit protection, an isolated-phase bus is used. Each phase of the circuit is run in a separate grounded metal enclosure. The only fault possible is a phase-to-ground fault, since the enclosures are separated. This type of bus can be rated up to ...
Interpretations for IEEE Std C37.23-1987 IEEE Guide for Metal-Enclosed Bus and Calculating Losses in Isolated-Phase Bus; IEEE P3004.7 - Recommended Practice for the Protection of Power Cables and Busway Used in Industrial and Commercial Power Systems; IEEE Busway Short Circuit Testing Procedures; IEEE Mathematical model of high voltage sandwich ...
In electric power distribution, a busbar (also bus bar) is a metallic strip or bar, typically housed inside switchgear, panel boards, and busway enclosures for local high current power distribution. They are also used to connect high voltage equipment at electrical switchyards, and low-voltage equipment in battery banks .
A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.
Enclosure comparison with normal wiring & with busbar system. Electrical busbar systems [1] (sometimes simply referred to as busbar systems) are a modular approach to electrical wiring, where instead of a standard cable wiring to every single electrical device, the electrical devices are mounted onto an adapter which is directly fitted to a current carrying busbar.
SWER's main advantage is its low cost. It is often used in sparsely populated areas where the cost of building an isolated distribution line cannot be justified. Capital costs are roughly 50% of an equivalent two-wire single-phase line. They can cost 30% of 3-wire three-phase systems. Maintenance costs are roughly 50% of an equivalent three ...
The most common type is designed for three-phase electric power, in which three isolated inductors are each wired in series with one of the three line phases. [8] Line reactors are generally installed in motor driven equipment to limit starting current, and may be used to protect Variable-frequency drives and motors.: [9])