When.com Web Search

  1. Ads

    related to: transformer winding resistance meter calculator formula

Search results

  1. Results From The WOW.Com Content Network
  2. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    In contrast to the parallel shunt component, the series component in the circuit diagram represents the winding losses due to the resistance of the coil windings of the transformer. Current , voltage and power are measured at the primary winding to ascertain the admittance and power-factor angle .

  3. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    An ammeter is connected in series with the primary winding. A voltmeter is optional since the applied voltage is the same as the voltmeter reading. Now with the help of a variac , the applied voltage is slowly increased until the ammeter gives a reading equal to the rated current of the HV side.

  4. Leakage inductance - Wikipedia

    en.wikipedia.org/wiki/Leakage_inductance

    Leakage inductance derives from the electrical property of an imperfectly coupled transformer whereby each winding behaves as a self-inductance in series with the winding's respective ohmic resistance constant. These four winding constants also interact with the transformer's mutual inductance. The winding leakage inductance is due to leakage ...

  5. Sweep frequency response analysis - Wikipedia

    en.wikipedia.org/wiki/Sweep_frequency_response...

    The distance between conductors of the transformer forms a capacitance. Any movement of the conductors or windings will change this capacitance. This capacitance being a part of complex L (inductance), R (Resistance) and C (Capacitance) network, any change in this capacitance will be reflected in the curve or signature. [1]

  6. Blocked rotor test - Wikipedia

    en.wikipedia.org/wiki/Blocked_rotor_test

    It is also known as short-circuit test (because it is the mechanical analogy of a transformer short-circuit test), [1] locked rotor test or stalled torque test. [2] From this test, short-circuit current at normal voltage , power factor on short circuit, total leakage reactance , and starting torque of the motor can be found.

  7. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The field produced by a single-phase winding can provide energy to a motor already rotating, but without auxiliary mechanisms the motor will not accelerate from a stop. A rotating magnetic field of steady amplitude requires that all three phase currents be equal in magnitude, and accurately displaced one-third of a cycle in phase.

  8. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A "delta" (Δ) connected transformer winding is connected between phases of a three-phase system. A "wye" (Y) transformer connects each winding from a phase wire to a common neutral point. A single three-phase transformer can be used, or three single-phase transformers. In an "open delta" or "V" system, only two transformers are used.

  9. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    Per-unit quantities are the same on either side of a transformer, independent of voltage level; By normalizing quantities to a common base, both hand and automatic calculations are simplified. It improves numerical stability of automatic calculation methods. Per unit data representation yields important information about relative magnitudes.