An isolation transformer is a transformer used to transfer electrical power from a source of alternating current (AC) power to some equipment or device while isolating the powered device from the power source, usually for safety reasons or to reduce transients and harmonics. [1]
The transformer breaks the conductive path between the ground terminals of the components, opening the loop, preventing ground loop currents from flowing, while allowing the AC signal to pass. Unlike other solutions such as breaking the cable ground shield, the isolation transformer can be used with a "floating" component (one with no ground ...
A transformer is the most widespread example of galvanic isolation. An opto-isolator is a very popular method of isolation in digital circuits. Cross-section of dual in-line package opto-isolators. Relative sizes of LED (red) and sensor (green) are exaggerated.
The isolation that could be created by each transformer is defeated by always having one leg of the transformers grounded, on both sides of the input and output transformer coils. Power lines also typically ground one specific wire at every pole, to ensure current equalization from pole to pole if a short to ground is occurring.
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
The back of an antique electrical room, still operational at a US plant as of 2014. All conducting busbars are open and operators must be careful not to touch them. An electrical room is a technical room or space in a building dedicated to electrical equipment. Its size is usually proportional to the size of the building; large buildings may ...
A drawing the intended locations of plant items and service routes in such detail as to indicate the design intent. The main features of detailed design drawings should be as follows: Plan layouts to a scale of at least 1:100. Plant areas to a scale of at least 1:50 and accompanied by cross-sections.
An isolation transformer links two circuits magnetically, but provides no metallic conductive path between the circuits. An example application would be in the power supply for medical equipment, when it is necessary to prevent any leakage from the AC power system into devices connected to a patient.