When.com Web Search

  1. Ads

    related to: 10 kg dcp fire extinguisher operation

Search results

  1. Results From The WOW.Com Content Network
  2. ABC dry chemical - Wikipedia

    en.wikipedia.org/wiki/ABC_dry_chemical

    Dry chemical powder is used on all classes of fires. Dry chemical powder puts out the fire by coating the burning material with a thin layer of dust, thereby separating the fuel from the oxygen in the air. The powder also works to interrupt the chemical reaction of fire, so these extinguishers are extremely effective at putting out the fire.

  3. Fire extinguisher - Wikipedia

    en.wikipedia.org/wiki/Fire_extinguisher

    Under NFPA 10 all commercial vehicles must carry at least one fire extinguisher, with size/UL rating depending on type of vehicle and cargo (i.e., fuel tankers usually must have a 20 lb (9.1 kg), while most others can carry a 5 lb (2.3 kg)).

  4. Fast Flow Extinguishers - Wikipedia

    en.wikipedia.org/wiki/Fast_Flow_Extinguishers

    In other words, a fast flow extinguisher expels a higher volume of agent in less time than a standard compliance flow extinguisher. As a result, fast flow extinguishers have lower UL class A&B ratings than compliance flow extinguishers (the class B numerical rating is the approximate square feet of burning fuel a novice operator could expect to ...

  5. Purple-K - Wikipedia

    en.wikipedia.org/wiki/Purple-K

    Purple-K, also known as PKP, is a dry-chemical fire suppression agent used in some dry chemical fire extinguishers. [1] It is the second most effective dry chemical in fighting class B (flammable liquid) fires after Monnex (potassium allophanate), and can be used against some energized electrical equipment fires (USA class C fires). [2]

  6. Gaseous fire suppression - Wikipedia

    en.wikipedia.org/wiki/Gaseous_fire_suppression

    Gaseous fire suppression, also called clean agent fire suppression, is the use of inert gases and chemical agents to extinguish a fire. These agents are governed by the National Fire Protection Association (NFPA) Standard for Clean Agent Fire Extinguishing Systems – NFPA 2001 in the US, with different standards and regulations elsewhere.

  7. Twin-agent fire extinguishing system - Wikipedia

    en.wikipedia.org/wiki/Twin-agent_fire...

    Dry chemical tank capacities range from 450 to 3,000 pounds (200 to 1,360 kg). AFFF solution capacity ranges from 50 to 250 US gallons (190 to 950 L). Dry chemical flow rates vary from 5 to 8 pounds (2.3 to 3.6 kg) per second and 35 to 60 US gallons (130 to 230 L) per minute for the foam for handline application [citation needed].